TROUBLESHOOTING SUGGESTIONS
10
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Water won’t heat
Circuit breaker tripped, main power switch
or tank heat switch turned off
Check / reset circuit breaker.
Turn switches on.
Temperature setpoint too low Set for desired temperature
Hi-Limit safety switch tripped Allow to cool, reset hi-limit reset
Damaged internal component or wiring
Examine wiring & connectors, controller,
power board and heating element.
Repair/replace as needed
Coffee level too high or low Timer out of adjustment Adjust timer
Brew chamber overows
Too many lter papers or wrong lter paper
Use one (1) genuine Bloomeld lter per
brew
Brew chamber dispense hole plugged Thoroughly clean brew chamber
Too much coffee or too ne a grind Use correct grind and amount of coffee
Sprays water from brew head Spray gasket improperly installed
Check/reinstall gasket on INSIDE of brew
head
No brew
Spray disk plugged Clean spray disk
Damaged internal component or wiring
Check switch, timer, solenoid, Repair,
replace as needed
No brew plus no ow from hot
water faucet
Water supply OFF Turn water supply ON
Solenoid inlet strainer plugged Clean strainer
Water lter (if used) plugged Replace lter element
No ow from hot water faucet Faucet plugged Disassemble faucet, clean
Continuous ow or drip from
brew head
Damaged solenoid Replace solenoid
Faucet water level probe limed-up or has
calcium deposits. “service tank” indicator lit
Delime faucet water tank
Poor coffee quality
Keep brewer and decanters clean. Install a taste and odor lter in water supply, and
replace cartridges regularly. Use a quality coffee with a consistent roast. Use proper
grind and amount of coffee per brew.