Specifications
TROUBLESHOOTING SUGGESTIONS
10
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Water won’t heat
Brewer unplugged or circuit breaker
tripped
Check power supply cord
Check / reset circuit breaker
Tank heater switch OFF Press tank heater switch to ON
Temperature setpoint too low Set for desired temperature
Hi-Limit safety switch tripped Allow to cool hi-limit will self-reset
Damaged internal component or wiring
Examine wiring & connectors, controller,
power board and heating element
Repair/replace as needed
Coffee level too high or low Timer out of adjustment Adjust controller
Brew chamber overows
Too many lter papers or wrong lter
paper
Use one (1) genuine Bloomeld lter per
brew
Brew Chamber dispense hole plugged Thoroughly clean brew chamber
Too much coffee of too ne a grind Use correct grind and amount of coffee
Sprays water from brew
head
Spray gasket improperly installed
Check/reinstall gasket on INSIDE of
brew head
Spray disk plugged Clean spray disk
No brew (faucet ows OK) Damaged internal component or wiring
Check brew switch, brew timer, &
solenoid. Repair, replace as needed
No brew plus no ow from
hot faucet
Water supply OFF Turn water supply ON
Solenoid inlet strainer plugged Clean strainer
Water lter (if used) plugged Replace lter element
No ow from hot water
faucet
Faucet valve turned OFF Turn faucet valve ON
Faucet plugged Disassemble faucet, clean
Poor coffee quality
Keep brewer and decanters clean. Install a taste and odor lter in water supply, and
replace cartrides regularly. Use a quality coffee with a consistant roast. Use proper
grind and amount of coffee per brew.
913 p/n 2M-75937 Owners Manual 8718, 8738 Coffee Brewer