682 OWNERS MANUAL for BOTTLED WATER AIRPOT COFFEE BREWERS MODEL 8382 for 3 Gallon and 5 Gallon Plastic Bottles Includes: Installation Operation Use & Care Servicing Instructions Model 8382 Brewer PRINTED IN UNITED STATES OF AMERICA p/n 75611 Rev.
WARRANTY STATEMENT The prices charged by Bloomfield Industries for its products are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to repair of defects without charge by a Bloomfield Industries Authorized Service Agency or one of its sub-agencies. This service will be provided on customer’s premises for non-portable models.
TABLE OF CONTENTS WARRANTY STATEMENT SPECIFICATIONS FEATURES & OPERATING CONTROLS PRECAUTIONS & GENERAL INFORMATION AGENCY APPROVAL INFORMATION INSTALLATION OPERATION CLEANING INSTRUCTIONS TROUBLESHOOTING SUGGESTIONS SERVICING INSTRUCTIONS EXPLODED VIEWS & PARTS LISTS WIRING DIAGRAM xi 1 2 3 3 4 5 8 10 11 16 19 Thank You for purchasing this Bloomfield Industries appliance.
FEATURES AND OPERATING CONTROLS Fig.
PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: Injury Hazard All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes.
INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: To enable the installer to make a quality installation and to minimize installation time, the following suggestions and tests should be done before the actual unit installation is started: CAUTION: Equipment Electrical Damage DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.
OPERATION START-UP For initial start-up, or if the brewer has not been used for an extended period of time: ♦ Be sure spray disk and brew gasket are properly installed in the brew head. ♦ Install a fresh bottle of water in the bottle ring. ♦ Allow basin and tank to fill. ♦ Plug unit into a properly grounded electrical receptacle. ♦ Draw water from the hot water faucet until all air is purged from the tank. NOTE: This brewer will not function as a “pour-over” brewer.
OPERATION (continued) WATER HEATER HI-LIMIT THERMOSTAT Water temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed to the thermostat, which controls line power to the heating element. THERMOBULB The setpoint temperature is adjustable at the thermostat. THERMOSTAT The element is protected from overtemperature by a hi-limit thermostat. Fig.
BREWING COFFEE PREPARATION Place one (1) genuine Bloomfield paper filter in the brew chamber. Add a pre-measured amount of fresh coffee grounds. Gently shake the brew chamber to level the bed of grounds. Slide the brew chamber into place under the brew head. CAUTION: Burn Hazard Exposed surfaces of the brewer and brew chamber may be HOT to the touch, and can cause serious burns.
CLEANING INSTRUCTIONS CAUTION: Burn Hazard Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. CAUTION: Electric Shock Hazard Do not submerge or immerse brewer in water. IMPORTANT: DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the brewer. PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool.
CLEANING INSTRUCTIONS (continued) PROCEDURE: Clean and Sanitize Basin Pan PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. FREQUENCY: Monthly TOOLS: #2 Phillips Head Screwdriver Mild Detergent, Food Equipment Sanitizer Clean Soft Cloth or Sponge 1. Disconnect brewer from electric power. Allow brewer to cool before cleaning. 2. Remove and empty decanters and brew chamber. 3. Remove water bottle. Drain water from hot water faucet until water no longer flows.
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Brewer unplugged or circuit breaker tripped Check power supply cord Check / reset circuit breaker Thermostat set too low Set for desired temperature Hi-Limit thermostat tripped Allow to cool Reset hi-limit (8786, 8788) Damaged internal component or Examine wiring & connectors, wiring thermostat and heating element Repair/replace as needed Coffee level low Water bottle empty Replace water bottle Too much coffee
SERVICING INSTRUCTIONS ACCESS PANELS Top panel is held by four screws at the corners. Front panel is held by two screws at the bottom and a retaining lip at the top. CAUTION Electric Shock Hazard Opening access panels on this brew may expose uninsulated electrical components. Disconnect brewer from electrical power before removing any panel Fig. 8 Access Panels TEMPERATURE ADJUSTMENT With the “READY TO BREW” light ON, draw a cup of water from the hot water faucet.
SERVICING INSTRUCTIONS (continued) IMPORTANT: Adjust timer with a full water bottle installed in the bottle ring. TIMER ADJUSTMENT The amount of water dispensed automatically during a brew cycle is controlled by the timer. Place empty airpot under brew chamber. Press BREW button. Brewer should dispense one airpot of water. To adjust amount: Remove brew chamber and button plug. Adjust knob on timer; clockwise increases time. Run several cycles to check amount of water delivered. Replace button plug.
SERVICING INSTRUCTIONS (continued) REPLACE HEATING ELEMENT Remove tank lid assembly per above. Remove two hex nuts holding element to cover. Pull element from mounting holes. Reassemble in reverse order. REPLACE SOLENOID Symptom: brewer will not flow water; or, brewer drips continuously from brew head.) Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water supply from brewer inlet fitting. Remove water bottle and top panel. Cut tie straps from solenoid hose connections.
SERVICING INSTRUCTIONS (continued) CAUTION CHEMICAL BURN HAZARD Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualified and experienced service personnel. IMPORTANT: DO NOT spill, splash or pour water or deliming solution into or over any internal component other than the inside of the water tank.
SERVICING INSTRUCTIONS (continued) 7. Set the tank back into the brewer. Reassemble the tank lid to the water tank. Make sure the gasket is properly in place, then reinstall the hold-down strap. 8. Reinstall wiring to heating element and thermostat. Reinstall the hi-limit thermostat . Verify that all internal components are dry, then reinstall the top panel. 10. Reconnect brewer to electrical supply. 11. Install the brew chamber without filter paper or grounds.
EXPLODED VIEW & PARTS LIST 8382 PLUMBING COMPONENTS ITEM PART# DESCRIPTION QTY 8 13 25 29 30 33 34 34a 40 41 42 43 45 46 54 59 60 61 62 66 68 69 114 200 T 83538 8043-5 8043-13 8783-1 82681 8543-42 84132 8543-45 8810-70 83384 85609 82241 83388 85634 8043-12 86771 8043-15 8043-11 85624 8043-24 8043-10 83385 8760-3 8942-6B TUBE, FAUCET SUPPLY 10” SILICONE STRAP, TANK LID HOLD DOWN ELBOW, BREW NOZZLE SILICONE FAUCET WASHER, FLAT SS 15/32 x 1-1/8 OD GASKET, SPRAY DISK SPRAY DISK BREW HEAD (must be drilled
EXPLODED VIEW & PARTS LIST (continued) ITEM PART# DESCRIPTION QTY 31 32 35 36 36t 37 45 50 56 63 67 8707-55 8718-31 8812-61 6407-15 8552-18 51217 83388 86280 8043-30 8043-83 8043-14 SWITCH, BREW MOMENTARY 120V INDICATOR LIGHT, GREEN 120V TIMER, 8 MIN POWER CORD, NEMA 5-15P TERMINAL BLOCK, 4P STRAIN RELIEF 90º CLAMP SOLENOID, BREW 120V THERMOSTAT, 199ºF SEAL, HEATING ELEMENT THERMOSTAT, HI-LIMIT 120V HEATING ELEMENT, 120V 1500W 1 1 1 1 1 1 1 1 2 1 1 17
EXPLODED VIEW & PARTS LIST (continued) ITEM PART# DESCRIPTION QTY 33 34 34a 70 71 72 73 73a 73b 75 78 80 80x 81 101 102 104 110 111 112 112x 113 113x 114 116 117 200 201 8543-42 84132 8543-45 8706-75 GASKET, SPRAY DISK SPRAY DISK BREW HEAD (must be drilled & riveted to install BUTTON PLUG, 2” DIA END CAP, SUPPORT PLASTIC SUPPORT, ALUMINUM BLACK ANODIZED LEG ADJUSTABLE LEG, METAL FOOT, RUBBER BUSHING, SHORTY HEYCO BUTTON PLUG 7/8” DIA BOTTLE RING (Model 8382) BOTTLE RING, OASIS (Model 8382OR) LABEL BA
WIRING DIAGRAM 19
Bloomfield Industries proudly supports CFESA Commercial Food Equipment Service Association Bloomfield Industries, Inc. Division of Carrier Commercial Refrigeration In US and Canada Telephone: 775-689-5700 Fax: 888-492-2783 Fax: 800-356-5142 (for orders only) website: www.wellsbloomfield.