User Manual
TROUBLESHOOTING SUGGESTIONS
8
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Water won’t heat
Dispenser unplugged or circuit breaker
tripped
Check power supply cord
Check / reset circuit breaker
Tank heater switch “OFF” Press switch to “ON”
Temperature setpoint too low Adjust thermostat for desired temperature
Hi-Limit safety switch tripped Allow to cool hi-limit will self-reset
Damaged internal component or wiring
Examine wiring & connectors, controller,
power board and heating element. Repair/
replace as needed
No ow from hot water
faucet
Water supply OFF Turn water supply ON
Solenoid inlet strainer plugged Clean strainer
Water lter (if used) plugged Replace lter element
Faucet plugged Disassemble faucet, clean
Water faucet drips
Debris in faucet seat Disassemble faucet, clean
Faucet damaged Examine faucet, repair or replace as needed
712 p/n 2M-76580 1222_1225_1226 Owmers Manual
712 p/n 2M-76580 1222_1225_1226 Owmers Manual