User Manual
2M-Z16993-631 ECO Style Brewers
2M-Z16993-631 ECO Style Brewers
DELIMING INSTRUCTIONS
8
PROCEDURE: Delime the Water Tank
PRECAUTIONS: Disconnect Power and allow brewer to cool.
FREQUENCY: As Required
TOOLS: Deliming Solution
Protective Gloves, Goggles & Apron
In areas around the water boiler, hard water will cause a mineral
to build-up as the unit is used. To keep the machine in best
condition and to prevent a build-up that would result in a poor
performance, We recommend that the deliming procedures be
performed every 6 months or after 200 cycles whichever comes
rst. Frequency of deliming will depend on the local water
characteristics.
1. Mix 2 quarts of deliming solution according to the
manufacturers directions.
2.
Place a paper lter into the brew chamber and put chamber
into position in the unit.
3.
Place an empty container under the brew chamber.
4. Pour the deliming solution into the pour-over located on top
of the unit.
5.
Turn the power switch on to begin the brew cycle.
6. Some of the HOT solution will begin dispensing into
the decanter / airpot, when that happens, turn the unit
“OFF”. Wait 30 minutes or as directed by the deliming
manufacturer.
7.
Continue running cold water thru brew cycles until the smell
of deliming solution is no longer present.
8.
Brewer is ready to use.
CAUTION:
CHEMICAL BURN
HAZARD
Deliming chemicals are caustic.
Wear appropriate protective
gloves and goggles during this
procedure.
Never siphon deliming
chemicals or solutions by
mouth.
This operation should only be
performed by qualied and
experienced personnel.
IMPORTANT: DO NOT spill,
splash or pour water or deliming
solution into or over any internal
component other than the inside
of the water tank.
NOTE: Normally, silicone
hoses do not need to be
delimed. Should deliming hoses
become necessary, Bloomeld
recommends replacing the
hoses.