User Manual
9
TROUBLESHOOTING SUGGESTIONS
2M-Z16993-631 ECO Style Brewers
2M-Z16993-631 ECO Style Brewers
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Water won’t heat
Brewer unplugged or circuit breaker
tripped
Check power supply cord
Check / reset circuit breaker
Hi-Limit thermostat tripped
Allow to cool
Reset hi-limit
Perform Deliming Procedures
Damaged internal component or wiring
Examine wiring & connectors, thermostat and
heating element, Repair/replace as needed
Pourover - no water or too little water
added at startup
Be sure to add sufcient water
Coffee level low (pour-over)
Not enough water poured in Increase water amount
Too much coffee grounds Adjust amount of grounds
Brew chamber overows
Too many lter papers or wrong lter
paper
Use one (1) genuine Bloomeld lter per brew
Brew chamber dispense hole plugged Thoroughly clean brew chamber
Too much coffee or too ne a grind Adjust coffee amount and grind
Too much water poured in Do not use more than 9 cups of water
Sprays water from brew
head
Spray gasket improperly installed Check/reinstall gasket on INSIDE of brew head
Spray disk plugged Clean spray disk
Poor coffee quality
Keep brewer, and decanters clean. Install a taste and odor lter in water supply, and replace
cartridges regularly. Use a quality coffee with a consistent roast. Use proper grind and
amount of coffee per brew.