User Manual
7. Set the tank back into the brewer. Reassemble the tank lid to
the water tank. Make sure the gasket is properly in place,
then reinstall the hold-down strap.
8. Reinstall wiring to heating element and thermostat. Reinstall
the hi-limit thermostat (if removed). For brewers with hot
water faucet, reassemble faucet piping. Verify that all internal
components are dry, then reinstall the top panel.
9. Reconnect brewer to electrical supply and, for automatic
brewers, reconnect water supply.
10. Install the brew chamber without lter paper or grounds.
Run at least three full brew cycles and discard all water
generated.
11. Brewer is ready to use.
NOTE: Normally, silicone hoses
do not need to be delimed.
Should deliming hoses become
necessary, Bloomeld recom-
mends replacing the hoses.
SERVICING INSTRUCTIONS (continued)
17
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer