User Manual

10
603 p/n 76451 8773_8774 Owmers Manual
TROUBLESHOOTING SUGGESTIONS
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Water won’t heat (be sure TANK
HEAT switch is ON)
Brewer unplugged or circuit breaker
tripped
Check power supply cord Check /
reset circuit breaker
Thermostat set too low Set for desired temperature
Hi-Limit thermostat tripped
Allow to cool, Reset hi-limit (8786,
8788)
Damaged internal component or wiring
Examine wiring & connectors,
thermostat and heating element,
Repair/replace as needed
Pour-over - no water or too little water
added at startup Be sure to add sufcient water
Coffee level low (pour-over)
Not enough water poured in Increase water amount
Too much coffee grounds Adjust amount of grounds
Coffee level too high or low
(automatic)
Timer out of adjustment
Adjust timer
Brew chamber overows
Too many lter papers or wrong lter
paper
Use one (1) genuine Bloomeld lter
per brew
Brew chamber dispense hole plugged Thoroughly clean brew chamber
Too much coffee or too ne a grind Adjust coffee amount and grind
Sprays water from brew head
Spray gasket improperly installed
Check/reinstall gasket on INSIDE of
brew head
Spray disk plugged Clean spray disk
No brew (automatic)
Water supply OFF Turn water supply ON
Solenoid strainer plugged Clean strainer
Water lter (if used) plugged Replace lter element
Bad BREW switch Replace switch
Damaged internal component or wiring
Examine wiring & connectors, brew
switch and solenoid Repair/replace as
needed
No ow from hot water faucet
Faucet valve turned OFF Turn faucet valve ON
Faucet plugged Disassemble faucet, clean
Poor coffee quality
Water not hot enough or too hot Adjust water temp 195-205ºF
Spray disk not installed
Properly installed spray disk and
gasket
Keep brewer, airpots and servers clean. Install a taste and odor lter in water
supply, and replace cartridges regularly. Use a quality coffee with a consistent
roast. Use proper grind and amount of coffee per brew.