User Manual
12
642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual
TROUBLESHOOTING SUGGESTIONS
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Water won’t heat
Brewer unplugged or circuit breaker
tripped
Check power supply cord, Check
/ reset circuit breaker
Temperature adjusted too low or set to
off
Turn on and set for desired
temperature. See page 15
Hi-Limit thermostat tripped
Allow to cool (1012, 1040 or
1072), or allow to cool and reset
hi-limit (1086, 1088)
Damaged internal component or wiring
Examine wiring & connectors,
controller, power board and
heating element, Repair/replace
as needed
Coffee level too high or low Timer out of adjustment Adjust controller. See page 16
Brew chamber overows
Too many lter papers or wrong lter
paper
Use one (1) genuine Bloomeld
lter per brew
Brew chamber dispense hole plugged Thoroughly clean brew chamber
Sprays water from brew head Spray gasket improperly installed
Check/reinstall gasket on INSIDE
of brew head
No brew while faucet ows OK
Spray disk plugged Clean spray disk
Damaged internal component or wiring
Check keypad, controller, power
board & solenoid, Repair, replace
as needed
No brew plus no ow from hot water
faucet
Water supply OFF Turn water supply ON
Solenoid screen plugged Clean solenoid screen
Water line strainer (if used) plugged Clean strainer
No ow from hot water faucet
Water lter (if used) plugged Replace lter element
Faucet valve turned OFF Turn faucet valve ON
Faucet plugged Disassemble faucet, clean
Poor coffee quality
Keep brewer, airpots and servers clean. Install a taste and odor lter in water
supply, and replace cartridges regularly. Use a quality coffee with a consistent
roast. Use proper grind and amount of coffee per brew.