TROUBLESHOOTING SUGGESTIONS
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Water won’t heat
Brewer unplugged or circuit breaker
tripped
Check power supply cord, Check
/ reset circuit breaker
Temperature adjusted too low or set to
off
Turn on and set for desired
temperature. See page 15
Hi-Limit thermostat tripped
Allow to cool (1012, 1040 or
1072), or allow to cool and reset
hi-limit (1086, 1088)
Damaged internal component or wiring
Examine wiring & connectors,
controller, power board and
heating element, Repair/replace
as needed
Coffee level too high or low Timer out of adjustment Adjust controller. See page 16
Brew chamber overows
Too many lter papers or wrong lter
paper
Use one (1) genuine Bloomeld
lter per brew
Brew chamber dispense hole plugged Thoroughly clean brew chamber
Sprays water from brew head Spray gasket improperly installed
Check/reinstall gasket on INSIDE
of brew head
No brew while faucet ows OK
Spray disk plugged Clean spray disk
Damaged internal component or wiring
Check keypad, controller, power
board & solenoid, Repair, replace
as needed
No brew plus no ow from hot water
faucet
Water supply OFF Turn water supply ON
Solenoid screen plugged Clean solenoid screen
Water line strainer (if used) plugged Clean strainer
No ow from hot water faucet
Water lter (if used) plugged Replace lter element
Faucet valve turned OFF Turn faucet valve ON
Faucet plugged Disassemble faucet, clean
Poor coffee quality
Keep brewer, airpots and servers clean. Install a taste and odor lter in water
supply, and replace cartridges regularly. Use a quality coffee with a consistent
roast. Use proper grind and amount of coffee per brew.