656 BLOOMFIELD INDUSTRIES 2 ERIK CIRCLE, P.O.Box 280 Verdi, NV 89439 U.S.A. Customer Service (775) 345-0444 Ext.502 fax (775) 345-0569 www.wellsbloomfield.com OWNERS MANUAL LX DECANTER BREWER MODELS 2212 2216 2216EX 2272 2274EX Includes INSTALLATION OPERATION USE & CARE SERVICE Model 2216 shown with optional decanters p/n 74733 Rev.
WARRANTY STATEMENT All electrical equipment manufactured by BLOOMFIELD INDUSTRIES is warranted against defects in materials and workmanship for a period of one year from the date of original installation or eighteen (18) months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser, except that: a. airpots carry a 30 day parts warranty only. b. dispensers; i.e., tea and coffee carry a 90 days parts warranty only, excludes decanters.
TABLE OF CONTENTS WARRANTY STATEMENT SPECIFICATIONS FEATURES & OPERATING CONTROLS PRECAUTIONS & GENERAL INFORMATION INSTALLATION INSTRUCTIONS AGENCY APPROVAL INFORMATION OPERATION USERS GUIDE CLEANING INSTRUCTIONS SERVICING INSTRUCTIONS Operational Adjustments Electrical Plumbing De-liming Heater Tank Diagnostics & Troubleshooting EXPLODED VIEW & PARTS LIST In-Line Models Step-Up Models WIRING DIAGRAMS In-Line Models Step-Up Models Inline Export models Step-up Export models xi 1 2 3 5 5 6 7 8 Thank You fo
FEATURES & OPERATING CONTROLS DECANTER (IN BREWING POSITION) 1 2 5 1. 2. 3. 4. 5. 6. 7. 8. Brew Indicator Heat Indicator Power Indicator Warmer Indicators Brew Key Cancel Key Power Key Main Warmer Key 9. 10. 11.
PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: Injury Hazard All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes.
INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: To enable the installer to make a quality installation and to minimize installation time, the following suggestions and tests should be done before the actual unit installation is started: CAUTION: Equipment Electrical Damage DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.
INSTALLATION INSTRUCTIONS (continued) 4. A water shut-off valve should be installed on the incoming water line in a convenient location (Use a low restriction type valve, such as a 1/4-turn ball valve, to avoid loss of water flow thru the valve. 5. NSF requires that the brewer be able to be moved for cleaning underneath. A flex line or loops of copper tubing will satisfy this requirement.
OPERATION OPERATING INSTRUCTIONS To over-ride the Brew Wait mode, press and hold the BREW key for 3 seconds when the brewer is in Brew Wait mode (i.e. when brew light is flashing). The brew will proceed immediately regardless of water temperature. This feature should only be used when testing water volume, otherwise the brew will proceed with the water below the precise brew temperature.
OPERATION (continued) USER’S GUIDE 1. Remove the brew chamber from under the spray head. Place one (1) genuine Bloomfield paper filter into the brew chamber. Add your choice of pre-measured ground coffee. Shake the brew chamber gently to level the coffee. Slide the brew chamber back into place. PAPER FILTER WARNING: Burn Hazard. This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from contact with dispensed liquids. CAUTION: Burn Hazard BREW CHAMBER 2.
CLEANING INSTRUCTIONS CAUTION: Burn Hazard Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. CAUTION: Electric Shock Hazard Do not submerge or immerse brewer in water. Do not pour or splash water into or over air vents, control panel or warmer plates. IMPORTANT: DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the brewer or decanters.
SERVICING — OPERATIONAL ADJUSTMENTS BREW TIMER BREW TEMP (IN SECONDS) 210 100 320 QUALITY TIMER DRIPOUT TIMER AFTER HOURS TIMER (IN 5 MIN INCR) (IN SECONDS) (IN ONE HR INCR) TEMP WATER 70 60 3 PROBE LEVEL PROBE 20 205 OFF 120 30 90 OFF 6 (IN °F) 194 185 OFF UNDER TOP COVER A B C D E CAUTION: Electric Shock Hazard A. B. C. D. E. Adjust Brew Time Adjust Brew Temperature Adjust Quality Timer Adjust Dripout Timer Adjust After Hours Timer 4.
SERVICING INSTRUCTIONS — ELECTRICAL OPERATION SEE PAGE 11 FOR COMPONENT NAMES / NUMBERS CONTROLLER WATER LEVEL PROBE FILL SOLENOID FILL BREW TIME DRIP OUT TIME CONTROLLER BREW SOLENOID BREW BREW LINE VOLTAGE HI-LIMIT T STAT BREW CANCEL BREW TEMP CONTROLLER WATER TEMP PROBE TRIAC HEATING ELEMENT WATER TEMPERATURE QUALITY TIMER CONTROLLER WARMER PLATES WARMER WARMER ELEMENT 1. Pressing the POWER key energizes the unit. The POWER LED will glow whenever the unit is ON. 2.
SERVICING INSTRUCTIONS — ELECTRICAL 3 4 5 7 8 15 17 18 20 27 28 32 27 28 WARMER MOUNTING PROBE, TEMPERATURE (THERMISTOR) THERMOSTAT, HI-LIMIT GROMMET PROBE, WATER LEVEL SLEEVE, WATER LEVEL PROBE ELEMENT, WATER HEATING ASSEMBLY, TRIAC & HEAT SINK BREW SOLENOID CONTROLLER COVER PLATE, WARMER ELEMENT, WARMER FILL SOLENOID 3 7 5 8 4 18 15 20 32 17 120/240V UNITS 4 E-MAX LX ELECTRICAL COMPONENT 11 120V UNITS
SERVICING INSTRUCTIONS — PLUMBING OPERATION SEE PAGE 13 FOR COMPONENT NAMES/NUMBERS 1. Water enters at the inlet fitting of the fill solenoid (32). The solenoid admits water via a command from the controller. NOTE: The solenoid has an internal strainer. To clean the strainer: Shut off water supply. Unscrew the plastic cap protruding from the rear of the brewer. Remove the cap, inlet fitting and washer. With pliers, grasp the bar of the strainer and pull straight out. Wash any debris from the strainer.
SERVICING INSTRUCTIONS — PLUMBING ITEM DESCRIPTION PART N0. USED ON 1 FAUCET, HOT WATER 8783-1 ALL 2 ASSEMBLY, WATER TANK (120V) ASSEMBLY, WATER TANK (240V) 83500 83753 2212, 2272 2216 6 GASKET, TANK LID 83499 ALL 9 TANK LID 83504 ALL RETAINING CLIP, TANK LID 83506 ALL 11 HOSE, OVERFLOW (2 pc SILICONE 4.5” LONG) 86014 ALL 12 HOSE, FAUCET SUPPLY (SILICONE, 10” LONG) 83538 ALL 13 TUBE, VENT (METAL, 2.
SERVICING INSTRUCTIONS — DE-LIMING HEATER TANK CAUTION - CHEMICAL BURN HAZARD De-liming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon de-liming chemicals or solutions by mouth. This operation must only be performed by qualified and experienced service personnel. IMPORTANT: DO NOT spill, splash or pour water or de-liming solution into or over any internal component other than the inside of the water tank.
SERVICING INSTRUCTIONS — DIAGNOSTICS & TROUBLESHOOTING) If the E-Max™ LX goes into an error mode as outlined below, it will probably be necessary to reset the brewer in order to test individual components. Note the reset procedure below: * FOR “LOW WATER” OR “OVERHEAT” ERRORS: PRESS & HOLD CANCEL FOR 3 SECONDS, OR RE-ENERGIZE THE BREWER (i.e. unplug for a few seconds, the plug in again.
EXPLODED VIEW — IN-LINE MODELS 16
PARTS LIST — IN-LINE MODELS 17
EXPLODED VIEW — STEP-UP MODELS 18
PARTS LIST — STEP-UP MODELS 19
WIRING DIAGRAM — IN-LINE MODELS 20
WIRING DIAGRAM — IN-LINE EXPORT MODEL 21
WIRING DIAGRAM — STEP-UP MODEL White #11 White #11 Rear Warmer Plate #3 120V 100 Watt Front Warmer Plate #2 120V 100 Watt Blue #4 Brown #5 White #11 White #12 Main Warmer Plate 120V 100 Watt Outlet Valve White #11 Orange #3 CONTROL BOARD Blue #2 White #10 120 Volt 1500 Watt Tank Heater Inlet Valve 1 WP3 2 WP2 Orange #8 3 WP1 Brown #1 Gate Black #9 Load Red #6 White #11 Hi-Limit Line White #10 Orange #7 Red #6 Brown #1 Blue #2 Black #9 Triac White #12 White #10 White #10 White #11 Bl
WIRING DIAGRAM — STEP-UP EXPORT MODEL 23
Bloomfield Industries proudly supports CFESA Commercial Food Equipment Service Association Bloomfield Industries, Inc. Division of Carrier Refrigeration In US PO Box 280, Verdi, NV 89439 Telephone: 775-345-0444 Service: 888-492-2782 Fax: 888-792-2783 website: www.wellsbloomfield.com In Canada Telephone: 877-507-1700 Service: 905-507-1700 Fax: 905-507-1777 website: www.bloomcan.