Specifications
658 2M-Z17969 Owners Manual 2121 E-Max Satellite Brewer
12
10. Pulse or Pre-Infusion Volume Options: these three (3) volumes have been preset at the factory
as the following sample programs. To change these settings refer to E-Max Programming Manual
2M-73674. refer to E-Max Programming Manual, Brew Settings Menu. If a particular brew
volume has utilized the pulse or pre-infusion option, that volume will be displayed with an asterisk
(*) after the volume.
As an example “Volume#2 3 G*” would indicate that the second programmed brew volume has
utilized the pulse or pre-infusion program options.
11. Keypadlock: This feature is OFF in the standard factory settings. To set the feature refer to
E-Max Programming Manual, Machine Settings Menu. If the Keypadlock feature is activated,
there will be no response by the brewer when the keys are depressed (except for the beep after a
key is depressed). To temporarily “unlock” the keypad, press and hold the CANCEL key for 6
seconds. A beep will be heard indicating the keypad is now “unlocked”, — a brew can be initiated,
warmer plates turned on or off, etc. The keypad will remain unlocked until the brew is completed,
then automatically return to keypadlock mode. If a brew is not initiated 60 seconds after
“unlocking”, the system will time out and return to the “locked” position.
12. View Filter Statistics: To view lter statistics, turn the brewer off. Press and hold the 1st key
(Brew), and depress the 3rd (ON/OFF) key. Total water volume will be displayed (TotalVol.).
Press the 3rd key to view the Filter Life (FltrLife:). Press the 3rd key to view the percentage of
the lter that has been used. (If the lter option is used, the lter life volume needs to be entered
in the program – see E-Max Programming Manual, Service & Counters Menu.)
OPERATION (continued)
DEFAULT PROGRAMS
Type: Satellite
Key Positions 4, 5 & 6
1 Galllon 1/2 Gallon 1-1/2 Gallon
Total Valve
215 142 322
Press 4th Key
Init. Valve Time 30
Pulse Delay 5
Pulse Valve On 10 25
Bypass Time 150 50 200
Brew Complete 45 30 60
Approximate Flow Rates
To determine brew time for a volume divide ounces by ow rate:
Brew Valve; .50oz sec
Bypass; .27oz sec