10. Pulse or Pre-Infusion Volume Options: these three (3) volumes have been preset at the factory
as the following sample programs. To change these settings refer to E-Max Programming Manual
2M-73674. refer to E-Max Programming Manual, Brew Settings Menu. If a particular brew
volume has utilized the pulse or pre-infusion option, that volume will be displayed with an asterisk
(*) after the volume.
As an example “Volume#2 3 G*” would indicate that the second programmed brew volume has
utilized the pulse or pre-infusion program options.
11. Keypadlock: This feature is OFF in the standard factory settings. To set the feature refer to
E-Max Programming Manual, Machine Settings Menu. If the Keypadlock feature is activated,
there will be no response by the brewer when the keys are depressed (except for the beep after a
key is depressed). To temporarily “unlock” the keypad, press and hold the CANCEL key for 6
seconds. A beep will be heard indicating the keypad is now “unlocked”, — a brew can be initiated,
warmer plates turned on or off, etc. The keypad will remain unlocked until the brew is completed,
then automatically return to keypadlock mode. If a brew is not initiated 60 seconds after
“unlocking”, the system will time out and return to the “locked” position.
12. View Filter Statistics: To view lter statistics, turn the brewer off. Press and hold the 1st key
(Brew), and depress the 3rd (ON/OFF) key. Total water volume will be displayed (TotalVol.).
Press the 3rd key to view the Filter Life (FltrLife:). Press the 3rd key to view the percentage of
the lter that has been used. (If the lter option is used, the lter life volume needs to be entered
in the program – see E-Max Programming Manual, Service & Counters Menu.)
OPERATION (continued)
DEFAULT PROGRAMS
Type: Satellite
Key Positions 4, 5 & 6
1 Galllon 1/2 Gallon 1-1/2 Gallon
Total Valve
215 142 322
Press 4th Key
Init. Valve Time 30
Pulse Delay 5
Pulse Valve On 10 25
Bypass Time 150 50 200
Brew Complete 45 30 60
Approximate Flow Rates
To determine brew time for a volume divide ounces by ow rate:
Brew Valve; .50oz sec