Operating instructions
. Prevent Brew Basket Overflow on 85 oz. Brew, 4 oz. of Ground Coffee. Total valve time of 236
seconds required for 85 oz. of water. Extend the delivery over a longer period of time, say 5¾
minutes, (or 344 seconds), to prevent overflow of brew basket, by having 3 valve delay period.
Initial Valve time is arbitrarily set at 62 seconds. Program the delay required (i.e. 344–236 = 108
seconds) over 3 pulse cycles, each with a delay of (108 ÷ 3) 36 seconds. To calculate the Pulse
Valve time: Total Valve Time minus Initial Valve Time divided by 3 pulse cycles: 236 – 62 ÷ 3 = 58
seconds.
· Init Vlv Time: 62
· Pulse Delay: 36
· Pulse Valve On: 58
· Total Valve: 236
Pulse Feature Examples TEA BREWERS:
1. Pre-Infuse Standard 3 gal. Brew. Total valve time of 319 seconds required for 128 oz. of water.
· Init Vlv Time: 60
· Pulse Delay: 30
· Pulse Valve On: 259
· Total Valve: 319
· Bypass Delay 20
· Bypass Valve 319
22
BREW BASKET #3 PREVENT OVERFLOW
1st pulse
2nd pulse
3rd pulse
0 60 120 180 240 300 360 420 480 540 600
ON
ON
ON
ON
OFF OFF OFF
OFF - DRIP OUT
62 sec.
60 sec.
58 sec. 58 sec. 58 sec.
36 sec.
36 sec.
36 sec.
Total Valve 236
Total Delay 108
Drip Out 60
Total Brew 404
0 60 120 180 240 300 360 420 480 540 600
60 sec
30 sec
259 sec
60 sec
One Pulse Cycle
Drip Out
ON
OFF
ON
OFF
#1 PRE-INFUSION
Total Valve: 319
Total Delay 30
Drip Out 60
Total Brew 409
PULSE BREW AND PRE-INFUSION (continued)