TROUBLESHOOTING SUGGESTIONS

Symptoms Possible Cause Suggested Remedy
Water won’t heat
Brewer unplugged or circuit
breaker tripped
Check power supply cord, Check /
reset circuit breaker
Temperature setpoint too low Set for desired temperature
Hi-Limit safety switch tripped Allow to cool hi-limit will self-reset
Damaged internal component or
wiring
Examine wiring & connectors,
controller, power board and heating
element. Repair/replace as needed
Coffee level too high or low Timer out of adjustment Adjust controller
Brew chamber overows
Too many lter papers or wrong
lter paper
Use one (1) genuine Bloomeld lter
per brew
Brew chamber dispense hole
plugged
Thoroughly clean brew chamber
Too much coffee or too ne a grind
Use correct grind and amount of
coffee
Sprays water from brew head Spray gasket improperly installed
Check/reinstall gasket on INSIDE of
brew head
No brew (faucet ows OK)
Spray disk plugged Clean spray disk
Damaged internal component or
wiring
Check keypad, controller, power
board & solenoid. Repair, replace as
needed
No brew plus no ow from
hot water faucet
Water supply OFF Turn water supply ON
Solenoid inlet strainer plugged Clean strainer
Water lter (if used) plugged Replace lter element
No ow from hot water faucet Faucet valve turned OFF Turn faucet valve ON
Poor coffee quality
Keep brewer and airpots clean.
Install a taste and odor lter in water supply, and replace cartridges
regularly.
Use a quality coffee with a consistent roast. Use proper grind and
amount of coffee per brew.