Specifications
643 2M-Z17088 Owners Manual 1883 E.B.C. Lo-Prole Airpot Brewer,
643 2M-Z17088 Owners Manual 1883 E.B.C. Lo-Prole Airpot Brewer,
643 2M-Z17088 Owners Manual 1883 E.B.C. Lo-Prole Airpot Brewer,
643 2M-Z17088 Owners Manual 1883 E.B.C. Lo-Prole Airpot Brewer,
TROUBLESHOOTING SUGGESTIONS
Symptoms Possible Cause Suggested Remedy
Water won’t heat
Brewer unplugged or circuit
breaker tripped
Check power supply cord, Check /
reset circuit breaker
Temperature setpoint too low Set for desired temperature
Hi-Limit safety switch tripped Allow to cool hi-limit will self-reset
Damaged internal component or
wiring
Examine wiring & connectors,
controller, power board and heating
element. Repair/replace as needed
Coffee level too high or low Timer out of adjustment Adjust controller
Brew chamber overows
Too many lter papers or wrong
lter paper
Use one (1) genuine Bloomeld lter
per brew
Brew chamber dispense hole
plugged
Thoroughly clean brew chamber
Too much coffee or too ne a grind
Use correct grind and amount of
coffee
Sprays water from brew head Spray gasket improperly installed
Check/reinstall gasket on INSIDE of
brew head
No brew (faucet ows OK)
Spray disk plugged Clean spray disk
Damaged internal component or
wiring
Check keypad, controller, power
board & solenoid. Repair, replace as
needed
No brew plus no ow from
hot water faucet
Water supply OFF Turn water supply ON
Solenoid inlet strainer plugged Clean strainer
Water lter (if used) plugged Replace lter element
No ow from hot water faucet Faucet valve turned OFF Turn faucet valve ON
Poor coffee quality
Keep brewer and airpots clean.
Install a taste and odor lter in water supply, and replace cartridges
regularly.
Use a quality coffee with a consistent roast. Use proper grind and
amount of coffee per brew.