Specifications

SERVICING INSTRUCTIONS
CAUTION:
SHOCK HAZARD
Opening access panels on
this dispenser may expose
uninsulated electrical
components.
Disconnect dispenser from
electrical power before
removing any panel.
ACCESS PANELS
REAR PANEL:
Remove rear panel to access hot water tank, thermostat,
heating elements, tubing, water level control and plumbing
connections.
Rear panel is held by four screws at the back. The anged top
portion ts over the body of the dispenser.
SOLENOID DOOR:
Solenoid door may be removed to aid in solenoid replacement.
This access panel is not normally removed.
Solenoid door is held by two screws and a retaining lip.
BUTTON PLUG:
Remove button plug to adjust thermostat temperature setting.
Fig. 3 Access Panels
9
2M-77729-713 OP MANUAL, 1223-2G & 1226-5G
2M-77729-713 OP MANUAL, 1223-2G & 1226-5G