Specifications

Arçelik/Blomberg 2009 ARES MLCD
8
kg
Tumble Dryer Service Handbook
26
Failure Codes :
Failure
code
Description Explanation
0 ERROR_CONSTANT_VALUE
The same valued is read
for 5 minutes
1 N/A N/A
2 ERROR_TANK_FULL Water tank is full
3 ERROR_ROTARY Rotary is broken
4 ERROR_HEATER_NTC
Heater NTC is shot circuit
or open circuit.
5 ERROR_DOOR_NTC
Door NTC is shot circuit or
open circuit.
6 ERROR_HEATER_HIGH_TEMPERATURE
Heater tempareture is
over limit.
7 ERROR_DOOR_HIGH_TEMPERATURE
Door tempareture is over
limit.
8 ERROR_CLEAN_FILTER Filter is full with fuzz
9 ERROR_BROKEN_STRAP V-belt is broken
10 ERROR_TEMPERATURE_DIFFERENCE
The temparature
difference between heater
NTC and Door NTC is 60
degrees
11 ERROR_HEATER_TEMPERATURE_RAPIDLY_INCREASED
Heater temparature is
rapidly increased between
15 and 25 seconds.
12 ERROR_DOOR_OPENED
The door is opened during
the cycle.
13 ERROR_HIGH_VOLTAGE The voltage is over 265V .
14 ERROR_LOW_VOLTAGE
The voltage is
under 165V .
15
ERROR_MAX_TIME
If the humidity sensor
drying programs reaches
its maximum time limits.
16
ERROR_DRUM_IDLE
Only beginning of sensor
drying programs.
17 ERROR_Program_ROTARY
If the Rotary is turned
during Run Mode.