Operation Manual

EN
1
0
10
Mounting the hood body
Before attaching the hood body, tighten the two
screws Vr located on the hood body mounting points.
Hook the hood body onto the screws 12a.
Fully tighten support screws 12a.
Adjust screws Vr to level the hood body.
12a
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150
or 120 mm, the choice of which is left to the installer.
To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
Fix the pipe in position using sufficient pipe clamps
(not supplied).
Remove any activated charcoal filters.
9
ø 120ø 150
RECIRCULATION VERSION AIR OUTLET
Push fit connection 15 onto the hood body outlet.
Insert the connection extension pieces laterally 14.1
in connection 15.
Make sure that the outlet of the extension pieces 14.1
is horizontally and vertically aligned with the chim-
ney outlets. If this is not the case, adjust the position
by either reversing the connection extension pieces
14.1 and then reassemble as described previously.
Ensure that the activated charcoal filters have been
inserted.
14.115