Specifications

Installation
21
Electrical Connection
Before making any electrical connections to this
unit, check that the power supply is adequate for
the voltage, amperage, and phase requirements
stated on the rating plate.
A wiring diagram accompanies this manual and is
also attached to the rear of the oven.
SG2136G
U.S. and Canadian installations
SG2136G ovens require a 5 amp, 60HZ , 1Φ,
208-240 VAC, 3 wire service consisting of L1, L2
and ground. Use 75_C wire and size to National
Electric or local codes.
Singl e phase units MUST NOT be connected to the
high leg of a three phase system. The high leg refers
to a potential o f 240 vol ts between one phase and
neutral. The remaining two legs have a po tential of
120 vo l ts between each phase and neutral.
General export installations
SG2136G ovens require a 5 amp, 50/ 60HZ (see
rating plate), 1Φ, 208-240VAC, 3 wire service con-
sisting of L1, neutral (or L2) and ground. Use 75_C
wire and size to National Electric or local codes.
SG2136E
U.S. and Canadian installations
SG2136E ovens are available in either 1Φ or 3Φ
options. Single phase models require a 90 amp,
60 HZ, 208-240 VAC (see rating plate) 3 wire ser-
vice consisting of L1, L2 and ground. Three phase
units require a 60 amp, 60 HZ, 208-240 VAC (see
rating plate) 4 wire service consisting of L1, L2, L3,
and ground. Use 75_C wire and size to National
Electric or local codes.
Australia and General Export installations
SG2136E ovens are available in either 1Φ or 3Φ
options. Single phase units require a 90 amp,
50/60 HZ (see rating plate), 208-240 VAC (see rat-
ing plate) 3 wire service consisting of L1, L2 and
ground. Three phase units require a 30 amp,
50/60 HZ (see rating plate), 208-240 VAC (see rat-
ing plate) 4 wire service consisting of L1, L2, L3
and ground. Use 75_C wire and size to National
Electric or local codes.
WARNING!!
Incorrect wiring will result in extensive
damage to electrical components and
possible fire in the control panel.
THE BLODGETT OVEN COMPANY CANNOT AS-
SUME RESPONSIBILITY FOR LOSS OR DAMAGE
SUFFERED AS A RESULT OF IMPROPER INSTAL-
LA TION.
SG2136G 1Φ
SG2136E Delta Power 3Φ
U.S. and Canadian Installations (or similar)
L1
L2
OvenSupply
L3
208 or 240
(typical)
L1
L2
208-240
OvenSupply
380/400/415
L1
L2
L3
OvenSupply
N
380/400/415
220/230/240
SG2136E Wye Power 3Φ
Australia and General Export Installations
380/400/415
SG2136E 1Φ
L1
L2
208-240
OvenSupply
Figure 18