KTT-E Series G-SB Series ELECTRIC TABLE TOP TILTING KETTLE GAS BOILER BASE STEAMER INSTALLATION MAINTENANCE INSTALLATION–- OPERATION OPERATION – - MAINTENANCE BLODGETT OVEN COMPANY BLODGETT OVEN COMPANY www.blodgett.com www.blodgett.
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
IMPORTANT - READ FIRST - IMPORTANT WARNING: THE UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. INSTALLATION MUST COMPLY WITH APPLICABLE CODES. NOTICE: Do not install the unit in any way which will bloc k the right side vents , or within 12 inches of a heat source such as a braising pan , deep fryer , char broiler or convection oven.
IMPORTANT - READ FIRST - IMPORTANT WARNING: DO NOT EXPOSE SKIN TO ESCAPING STEAM. SEVERE BURNS CAN RESULT. CAUTION: MAKING ANY ELECTRICAL OR MECHANICAL CHANGE IN THE UNIT WITHOUT PRIOR WRITTEN APPROVAL FROM ENGINEERING WILL VOID ALL WARRANTIES. WARNING: ALL POTENTIAL USERS OF THE EQUIPMENT SHOULD BE TRAINED IN SAFE AND CORRECT OPERATING PROCEDURES. WARNING: DO NOT OPERATE THE UNIT UNLESS ALL REMOVABLE PANELS (RIGHT, LEFT, FRONT AND REAR) HAVE BEEN PROPERLY INSTALLED.
Table of Contents Important Operator Warnings ..................................................... page 1-2 References..................................................................................... page 3 Equipment Description.................................................................. page 4 Water Quality and Treatment ......................................................... page 5 Installation ..................................................................................
Equipment Description WARNING THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH ELECTRICITY AND/OR GAS, AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES. The G-SB Steamer is designed to bring you years of service. It has two stainless steel cavities (cooking chambers) and a control compartment, which houses the electrical components and steam valves.
Water Quality & Treatment REDUCE SCALE PROBLEMS BY USING AND MAINTAINING A WATER SOFTENER FOR YOUR STEAMER! It is essential that the boiler be supplied with water that will not form scale at an unacceptable rate. The boiler was engineered to minimize scale, but its formation depends on water hardness and how much the unit is used. In some areas of the United States the water is low enough in mineral content to avoid scale build-up. However, most water supplies carry heavy loads of minerals.
Installation WARNING MAKING ANY ELECTRICAL OR MECHANICAL CHANGE IN THE UNIT WITHOUT PRIOR APPROVAL WILL VOID ALL WARRANTIES. WHEN THE UNIT IS RECEIVED, IMMEDIATELY INSPECT IT FOR EXTERNAL OR INTERNAL DAMAGE. REPORT ANY DAMAGE TO THE FREIGHT CARRIER. After inspection, keep the unit in its shipping container until it is installed. It can be installed on combustible and non-combustible floors.
Installation WARNING THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES. CAUTION SHIPPING STRAPS ARE UNDER TENSION. THEY CAN SNAP BACK VIOLENTLY AND CAUSE INJURY WHEN CUT. 2. 3.
Installation 5. 8 OM-G-SB Utility Connections 1. Cold water (untreated). 2. Cold water (treated). 3. Hot water (for faucet on 36” and wider units with kettles). 4. Steam outlet (for power take-off). 5. Gas, natural or propane. 6. Drain (for boiler, steamers and condenser spray). Also for kettle condensate and sink where used. 7. Electrical (conduit through underside, terminals at the right on the inside).
Initial Start-Up After the unit has been installed, test it to ensure that it is operating properly. 1. Remove literature and packing material from the interior and exterior of the unit. 2. Make certain the water supply is turned on. 3. Turn on electrical power to the unit. 4. Make sure the gas supply line is open, and turn on the gas valve. Turn the knob on the gas valve to the “ON” position. Operating Controls are located on the front of the cabinet base unit.
Initial Start-Up WARNING STAY AWAY FROM STEAM COMING OUT FROM THE UNIT. STEAM CAN CAUSE SEVERE BURNS. 8. When steam is available for the cavity, choose one of the following: a. Set the timer to the desired time for timed steaming. b. Turn the timer to the manual ON position for continuous steam. NOTE: The door must be shut before steam will enter the cavity. If the door is opened when the timer is on, the flow of steam will stop. c. Let the steamer sit idle until needed. 9.
Operation WARNING ALL POTENTIAL USERS OF THE EQUIPMENT SHOULD BE TRAINED IN SAFE AND CORRECT OPERATING PROCEDURES. A. Controls Operating controls are located on the front panel of the unit. 1. The on/off switch starts the unit or shuts it off. 2. The RESET indicator lights to show that the boiler has filled with water and that the main burners can ignite. 3. The start switch (momentary) lights the main burners.
Operation WARNING ANY POTENTIAL USER OF THE EQUIPMENT SHOULD BE TRAINED IN SAFE AND CORRECT OPERATING PROCEDURES. WARNING WHEN YOU OPEN THE DOOR, STAY AWAY FROM THE STEAM COMING OUT OF THE UNIT. THE STEAM CAN CAUSE BURNS. B. Operating Procedure 1. Turn on the unit’s water supply. 2. Turn on electrical power to the unit. 3. Turn on the gas supply to the unit, and turn on the gas valve. Turn the control knob on the gas valve to the “ON” position.
Operation 7. Turn the timer to one of the following settings: a. If you want to steam for a definite period of time, set the timer to that time. Steam will be delivered to the cavity for that time, and then stop. A buzzer and red LED will indicate that the timed cycle is complete. Steam flow stops. b. If you want to steam continuously, turn the timer to the ON position. A green light will come on. Steam will be delivered to the cavity until the timer is returned to OFF. 8. Open the door. 9.
Sequence of Operation CAUTION WAIT AT LEAST 60 SECONDS BEFORE ATTEMPTING TO RE-LIGHT THE MAIN BURNER AFTER IT SHUTS OFF. CAUTION ESCAPING STEAM MAY CAUSE SEVER BURNS. STAY AWAY FROM THERMOSTATIC AIR VENT AND PRESSURE RELIEF VALVES. When electrical power is turned on to the unit, the following happens: • The drain valve closes • The water valve opens • The unit fills with water As the boiler fills, the water is detected by two probes. The first of these is the “mid” probe, which activates the RESET light.
Steamer Compartment Cleaning WARNING DISCONNECT THE POWER SUPPLY BEFORE CLEANING THE OUTSIDE OF THE STEAMER. KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS. NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT. To keep your Steamer in proper working condition, clean the unit each day. This regular cleaning will reduce the effort required to clean the cavities. A. 1. 2. 3.
Boiler Cleaning WARNING WATER AND VALVES MAY BE VERY HOT, AND MAY CAUSE BURNS. PROTECT HANDS FROM HOT SURFACES AND WATER. Whenever the boiler is turned off and allowed to cool to about 130ºF, it drains automatically. This should be done every day to minimize scale buildup inside the boiler. WARNING USE SAFETY GLASSES AND RUBBER GLOVES AS RECOMMENDED BY DE-LIMING AGENT MANUFACTURER. In addition to this draining, however, the following cleaning procedure should be followed using a regular schedule.
Cleaning WARNING SOLUTION AND VALVES WILL BE VERY HOT, AND MAY CAUSE BURNS. PROTECT HANDS FROM HOT SURFACES AND CONTINUE TO USE PROTECTIVE GLOVES. 13. Set steamer timers for 10 minutes. 14. When steamer timers sound, turn them to OFF and open the doors. 15. When the fans have stopped, remove fan baffle partitions using protective gloves, and rinse with clean water. 16. Completely wipe out steamer chambers using a degreaser and nylon pad, if necessary. Rinse thoroughly with clean water. 17.
Steamer Maintenance WARNING BEFORE REPLACING ANY PART TURN OFF THE ELECTRICAL POWER TO THE UNIT. DEATH OR INJURY COULD RESULT FROM CONTACT WITH HIGH VOLTAGE. The Steamer is designed for minimum maintenance, and no user adjustments should be necessary. Certain parts may need replacement after prolonged use. If there is a need for service, only Authorized Service Representatives should do the work.
Maintenance WARNING USE ONLY MANUFACTURER-SUPPLIED PARTS. USING SUBSTITUTE, UNAUTHORIZED OR “GENERIC” PARTS CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT. WARNING DO NOT EXPOSE SKIN TO ESCAPING STEAM. SEVERE BURNS MAY RESULT. Your boiler is designed to minimize maintenance, but certain parts may need to be replaced after prolonged use. For the most part, no user adjustments should be necessary. If a need for service arises, only Authorized Representatives should perform the work.
Troubleshooting Do not operate the unit if it malfunctions or has damaged or broken parts. Steam boilers are designed to operate smoothly and efficiently when maintained properly. However, the following is a list of checks to make if there is a problem. Electrical schematics are provided in this manual, and inside the unit electrical enclosure. IF THE ITEM ON THE LIST IS MARKED WITH (X), THE WORK SHOULD ONLY BE DONE BY A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE.
Troubleshooting SYMPTOM WHO WHAT TO CHECK Timer control will not operate. User a. Is the electrical supply turned on? b. Is the ON/OFF switch in the base cabinet turned on? c. Is boiler started? Is the green light in the ON/OFF switch lit? d. Are any fuses blown? No steam to cavities. User a. Has steam pressure developed? b. Is steam supply turned on? c. Is the door closed? (Doors must be closed before steam will enter the cavity). Door leaking steam or water. User a.
Steamer Cavity 22 OM-G-SB Parts List
Parts List Steamer Cavity Key Description Part # Key Description Part # 1 UPPER CAVITY DRAIN HOSE 088847 20 TRANSFORMER, 75VA 110V - SG 121715 2 MOTOR ASSEMBLY 096740 27 BUSHING - SG 012864 3 TIMER 096826 28 LOCK WASHER #8 - SG 12971 4 KNOB, TIMER 123100 29 RELAY, DPDT 24VAC - SG 121733 5 PC BOARD, HY-PLUS LIGHT AND TIMER 130457 30 SCREW, 8-32 X 3/8 - SG 069789 6 BRACKET, BOARD MTG 096888 31 VALVE, SAFETY 143470 7 STEAMER CONTROL BOARD 102222 32 MANIFOLD FITTI
Parts List Motor/Fan Assembly Key Description Part # 1 MOTOR 096739 2 SLINGER WASHER 096831 3 MOTOR MOUNTING PLATE 094134 4 SHAFT SEAL 096868 5 PLATE SEAL HOLDER 096752 24 OM-G-SB
Parts List Sheet Metal & Doors Key Description Part # 1 COVER, RIGHT SIDE (6-PAN) 143778 1 COVER, RIGHT SIDE (10-PAN) 159866 2 COVER, LEFT SIDE (6-PAN) 123184 2 COVER, LEFT SIDE (10-PAN) 159867 3 COVER ASSEMBLY, TOP 123182 4 SCREW, 10-32 X 3/8 TRUSS HEAD 004173 5 RETAINER, TOP 123156 6 SCREW, 8-32 X 3/8 SLOTTED HEX HEAD 004173 7 DOOR HANDLE 070123 8 DOOR HINGE (6-PAN) 130868 8 DOOR HINGE (10-PAN) 125928 9 OUTER DOOR (6-PAN) 130858 9 OUTER DOOR (10-PAN) 125922 OM-G
Parts List Door & Cavity Hardware Key Description Part # 1 DOOR GASKET (6-PAN) 094147 1 DOOR GASKET (10-PAN) 125907 2 DOOR HANDLE 070123 3 DOOR CAM 074252 4 MAGNET ASSEMBLY 069762 5 U-CHANNEL ASSY. (6PAN) (INCL. DOOR SPRING 078911) 094144 5 U-CHANNEL ASSY. (10PAN) (INCL.
Drain Box w/Spray Condenser Key Description Parts List Part # 1 SOLENOID VALVE (SPRAY CONDENSER) 099221 2 HOSE D “ ID X 8” LONG 099282B 3 RUBBER FLAP 099213 4 SPACER 099212 5 HOSE, OUTLET 1 “ID X 3” LONG 099280B 6 ANCHOR COUPLING, D” NPT N89267 OM-G-SB 27
Parts List Gas Boiler Key Description Part # 1 BOILER WELDMENT 2 SIGHT GLASS ASSEMBLY 121754 3 KIT, REPAIR - SIGHT GLASS 097099 4 FLUE ASSEMBLY 099217 5 SAFETY VALVE (15PSI) 102297 6 PRESSURE RELIEF VALVE (12PSI) 099228 7 WATER LEVEL PROBES (LO, MED, HI) 076526 8 SOLENOID VALVE (WATER-IN) 099220 9 CHECK VALVE 004187 10 AIR VENT 145167 11 VACUUM BREAKER 090787 12 GLOBE VALVE 1/2”NPT 099255 13 OPERATING PRESSURE SWITCH-91/2 PSI 099222 14 HI-LIMIT PRESSURE SWITCH-141
Parts List Burner & Gas Valve Key Description Part # 1 BAFFLE PLATE 083076 2 PILOT BURNER MOUNTING BRACKET 102257 3 PILOT BURNER W/ SPARK IGNITER-SENSOR 102258 4 SHIELD FOR PILOT BURNER 102260 5 FLAME DEFLECTOR (SINGLE LOOP) HOLDER FOR #640 056965 7A MAIN BURNER ASSY 0-2000 FT. ELEV.(INCL. (29) GAS JETS W/ #54 DRILL DIA HOLE) FOR NATURAL GAS 047267 7A MAIN BURNER ASSY 0-2000 FT. ELEV.(INCL.
Parts List Boiler Electrical Controls Key Description 4 Part # 1 SWITCH “ON/OFF” 088876 2 SWITCH “START” (MOMENTARY) 099290 3 INDICATOR LIGHT “RESET” 099289 4 LIGHT, INDICATOR AMBER 116384 5 LIGHT, INDICATOR RED (2) 116383 6 TERMINAL BLOCK, 2-POLE 003887 - BUSHING SNAP 11/16” ID 012864 7 CIRCUIT BOARD SUPPORT 099292 8 WATER LEVEL CONTROL BOARD ASSEMBLY 116016 9 LUG, GROUND 14-6 AWG 119829 10 CIRCUIT BREAKER 119860 11 TRANSFORMER, 75VAC 121715 12 RELAY, DPDT 24VAC 3
Steamer Cavities Electrical Schematic OM-G-SB 31
Electrical Schematic Boiler S2 2 1 1 3 TO 120V AC 4 HN 3 1 CB1 10A GRN 4 B A BLACK FROM T2 @ STEAMER BLACK 120V VIEWED FROM REAR 2 WHITE TO T3 @ STEAMER SWITCH CONTACT ARRANGEMENT COM 2 GND 2 4 24VAC 75VA HI J2 1 1 RED 3 4 RED LO P1 T1 WHITE 11 RED 1 S1 2B LUE BLUE DUAL WATER LEVEL CONTROL 3 ORANGE WHITE 2 SPRAY VALVE 3A ON SWITCH P2 1 2 J1 1 R 1 12 BLUE 9 BLACK 1 2 TSTAT CLOSES @ 170° BLUE H N01 C1 NC1 L1 LLCO L2 NC2 C2 NO2 G 2 DRAIN VA
Service Log Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchase Order No: For Service Call: Date Maintenance Performed Performed By OM-G-SB 33
BLODGETT OVEN COMPANY www.blodgett.