Repair manual

MT3855
1
OVEN SPECIFICATIONS
VENTILATION REQUIREMENTS
The hood should completely cover the unit with an
overhang of at least 6" (15 cm) on all sides not adjaĆ
cent to a wall. The distance from the floor to the
lower edge of the hood should not exceed 7' (2.1
m). The ventilation system should replace 80% of
the exhaust volume with fresh make up air.
TABLE 1 should be used as a guideline.
Single Double Triple
CFM 1000Ć1400 2400Ć3300 3600Ć5000
M
3
/min 28 Ć 40 68Ć93 102Ć142
TABLE 1
ELECTRICAL SPECIFICATIONS
NOTE: Three Phase hookup is not permitted.
WARNING: DO NOT INSTALL A HIGH LEG" TO
ANY CONVEYOR OVEN!
Installations within the U.S.
The MT3855 requires a 15 Amp, 60HZ, 1F,
208Ć240VAC, 4 wire service consisting of L1, L2,
neutral and ground. See FIGURE 1. Use 90C wire
and size to National Electric or local codes.
Installations outside the U.S.
The MT3855 requires a 15 Amp, 50Hz, 1F, 230
VAC, 3 wire service consisting of L1, neutral and
ground. See FIGURE 1. Use 90C wire and size
wire according to local codes.
U.S. Installations
L1
N
L2
120
120
208Ć240
OvenSupply
Export Installations
L1
N
220Ć230
OvenSupply
FIGURE 1