Conveyor Ovens Installation, Operation, Maintenance Manual MT3855G-G

Maintenance
19
Cleaning
WARNING!!
Alway s disconnect the p ower supply be-
fore cleaning or servicing the oven.
WARNING!!
If the oven needs to be moved, the gas
must be turned off and disconnected from
the unit before removing the restra int. Re-
connect the restraint after the oven has
been returned to its original location.
Follow this recommended cleaning schedule for
proper oven performance.
Daily:
1. Clean the conveyor belt using a wire brush. Al -
low any foreign materialto drop into the crumb
pans.
2. Remove the product stop and both crumb
pans from the ends of the conveyor.
3. Empty and clean the crumb pans with a hot
water/detergent mix. Rinse with clean water.
Every Three Mo nths:
1. Unplug the 220V power cord.
2. Disconnect the gas. Be sure that the oven
control cables have 2-3 feet of slack
3. Clean the cooling fan louvers on both sides of
theovenwithasoftbrush.
Every Six Months:
1. Remove the product stop and both crumb
pans from the ends of the conveyor.
2. Remove both upper end plugs. Loosen the
wing nuts on the bottom of each end plug.
Figure 17
3. Remove the air plates as follows:
a.) Loosen the wing screws holding the air
plate retainers in place. Remove the four
wing screws from the control box end of
the oven.
Figure 18
b.) Slide the air plates straight out from both
ends of the oven.
Figure 19