OVEN SPECIFICATIONS
VENTILATION REQUIREMENTS
The hood should completely cover the unit with an
overhang of at least 6" (15 cm) on all sides not adjaĆ
cent to a wall. The distance from the floor to the
lower edge of the hood should not exceed 7' (2.1
m). The ventilation system should replace 80% of
the exhaust volume with fresh make up air.
TABLE 1 should be used as a guideline.
Single Double Triple
CFM 500Ć600 1000Ć1200 1500Ć1800
M
3
/min 14 Ć 17 28Ć34 42Ć51
TABLE 1
ELECTRICAL SPECIFICATIONS
NOTE: Three Phase hookup is not permitted on
gas models.
WARNING: DO NOT INSTALL A HIGH LEG" TO
ANY CONVEYOR OVEN!
Installations within the U.S.
MT2136G ovens require a 15 amp, 60HZ, 1F,
120/208Ć240 VAC, 4 wire service consisting of L1,
L2 neutral and ground. See FIGURE 1. Use 90C
wire and size to National Electric or local codes.
MT2136E ovens are available in either 1F or 3F opĆ
tions. Single phase models require a 15 amp, 60
HZ, 208Ć240 VAC 3 wire service consisting of L1, L2
and ground. Three phase units require a 15 amp,
60 HZ, 208Ć240 VAC 4 wire service consisting of L1,
L2, L3, and ground. See FIGURE 1. Use 90C wire
and size to National Electric or local codes.
MT2136G - U.S. Installations
MT2136E - Single Phase U.S. Installations MT2136E - Three Phase U.S. Installations
L1
L2
OvenSupply
L3
208Ć240
L1
L2
208Ć240
OvenSupply
L1
N
120
OvenSupply
L2
120
208Ć240
FIGURE 1