Repair manual

ENHANCEMENTS
4 --- 4
IGNITER AND FLAME RODS
FIGURE 5 illustrates the correct location of the ig-
niter and flame rod.
Gap .109 (7/64) from
center of hole to edge
of probe
Both are fixed and should not move or swing.
Gap .109 (7/64) from
center of hole to edge
of probe
FIGURE 5