Owner`s manual
Manual Control Startup
4
Gas Pressure Adjustments
THE F OLLOWING STARTUP PROCEDURES MUST
BE PERF ORMED BY A QUALIFIED T E C HNICIAN
ONLY.
REGULATED GAS PRESSURE
NOTE: Gas models only.
Incomi ng static gas pressure to the unit, with all the
gas appliances drawing from the supply, should be
a minimum of 5.5” W.C. (13.7 mbar) for natural gas
and 11” W.C. (28 mbar) for propane gas.
The manifold pressure, if measured after the regu-
lator located inside the control box, must be 3.5”
W. C. (9 mbar) for natural gas and 10” W.C. (25
mbar) for propane gas.
The pressure can be checked at the tap on either
the dual regulated gas valve or the solenoid valve.
Turn the adjusting screw on the left front side of the
dual regulated valve to adjust the gas pressure.
Turn the screw clockwise to raise the gas pressure
and counter-clockwise to lower it.
PRIMARY AIR ADJUSTMENT
NOTE: Gas models only.
The air shutter disc on the burner blower motor, lo-
cated inside the control box at the top of the as -
sembly, is factory adjusted to provide t he most effi-
cient blue flame possible at sea level.
1. Visually examine the quality of the flame.
2. If it needs adjusting, increase or decrease the
air mixture to attain the best flame quality.
Pressure Tap
Regulator
Cap
Regulator
Adju stment
Figure 2