Repair manual

ASSEMBLY
2-2
4. Install the inner and outer master links as
shown in FIGURE 3.
Master
Link
Direction of
Travel
FIGURE 3
Unless otherwise specified, the conveyor travel is
factory set for leftĆtoĆright operation when facing
the drop down door. If a direction change is reĆ
quired, the polarity of the drive motor must be reĆ
versed. To change the polarity of the drive motor,
disconnect the oven from the power source and inĆ
terchange the black and white motor leads at the
D.C. Controller Board located within the control
box. If the polarity of the motor is changed to
rightĆtoĆleft belt travel, the conveyor belt must
be installed from the left side of the oven inĆ
stead of the right side.
NOTE: Reconfigure the air plates whenever the
conveyor belt direction of travel is
changed. See FIGURE 4.
Burner Side
Front Of Oven
7 holes
Air Hole
BlockĆoff
Slots
Closed
Slots
Closed
Burner Side
Front Of Oven
7 holes
Air Hole
BlockĆoff
Slots
Closed
Slots
Closed
DIRECTION OF TRAVEL
DIRECTION OF TRAVEL
FIGURE 4