Operating instructions
4
2.0 SERVICE CONNECTIONS
Unless otherwise specified, Field Wire Electrical Connection to be 120
Volts, 60 Hz. single phase with grounding wire. Unit furnished with 8’ cord
and 3 prong plug.Total max amps 2.0.
GAS CONNECTION: Supply gas through 3/4” pipe.
NA
TURAL 6”-14”W.C. (152mm - 355mmW.C.)
PROPANE 12” - 14”W
.C. (305mm - 355 mmW.C.)
Contact manufacturer for installation over 2,000 ft. elevation.
H
C
COLD WATER - 3/8” O.D. tubing to faucet (optional)
HOT WA
TER - 3/8” O.D. tubing to faucet (optional)
SAFTE
Y RELIEF
VALVE
AIR VENT
25.388 [645]
3 [76]
HC
4.75 [121]
23.75 [603]
1.50 [38]
5.38 [137]
Ø20 [508]
Ø16.75
[425] I.D.
30 [762]
15.88 [403]
6 [752]
23.88 [607]
32.88 [835]
55.75 [1416]
OPTIONALFAUCET
POUR PATH
11.25 [285]
15 [381]
17.25 [483]
7.75 [197]
5.5 [140]
FLANGED FOOT DETAIL
4 EQUALLY SPACED
Ø7/16” [
11MM] HOLES
ON 3 [76] B.C.
CLEARANCES:
SIDES = 0 [0]
BACK = 6 [152]
FOR USE ON NON-COMBUSTIBLE FLOORS ONLY