Sequence of Operation
Thefollowing“action-reaction”outlineisprovidedtohelptheuserunderstandhow
the equipment works.
When the operator starts up the kettle by turning the operating thermostat dial from 
“OFF”toadesiredsetting,thethermostatswitchcloses.Thislightsuptheheating
indicator light and causes the contactors to close, allowing power to flow to heating 
elements.
When the temperature of the steam jacket reaches the value corresponding to the 
dial setting, the thermostat switch opens. This turns off the heating indicator light and 
causes the contactors to open, cutting the power to the heaters.
As soon as the thermostat senses that the kettle is cooling below the set point, the 
thermostat switch closes, the heating indicator light comes on, the contactors close, 
and the heaters come on again. On-off cycling continues, keeping the kettle at the set 
temperature. This is why the heating indicator light cycles on and off during normal 
operation.
If steam pressure greater than 30 PSI is generated in the jacket, the safety valve will 
open and relieve the excess pressure.
If the jacket water level gets too low, the high- limit control will open and shut off 
power to the elements until the kettle cools. This will prevent the heating elements 
from overheating.
Settingtheoperatingthermostatdialto“OFF”shutsdownallcontrolandheating
circuits.