Hydrovection Owners Manual
9
Installation
Plumbing Connections
WATER CONNECTION
NOTE:  Must use COLD WATER ONLY.
Connect  the  appliance  to  quality  water  via  a  pressure 
hose with 3/4” GHT (19mm) couplings. See Figure 6 for 
connections. A shut off valve is to be provided adjacent to 
the oven.
 WARNING!!
Operating the appliance without a water pres-
sure regulator installed will invalidate your 
warranty.
This product must be installed by a licensed Plumber or 
Gas Fitter when installed within the Commonwealth of 
Massachusetts.
DRAIN CONNECTION
The drain should be run to an open oor drain avoiding 
exible  hose  that  could  sag  and  allow  trapped  water  to 
accumulate. The customer must supply the piping from 
the oven to the drain.
Specic water/drain connection for City of Los Ange-
les
1.  Each drain line from the appliance shall be routed 
without dips or sags to terminate above the ood level 
rim of an approved indirect waste receptor.
2.  The appliance shall be installed in accordance with 
the manufacturer’s printed instructions and the LAPC 
and LAMC, 1999 editions.
3.  A backow protection device may be required by lo-
cal codes. If so, install on the potable water system 
directly ahead of the appliance. The backow protec-
tion device shall be any of the following: an approved 
pressure type vacuum breaker installed at least 12” 
above the highest point of use, a double check valve 
backow  preventer  or  a  reduced  pressure  principal 
backow preventer.
Figure 6 
HV-100E & HVH-100E
HV-100G & HVH-100G
A =  Electrical Connection 
B =  Gas Connection 
C =  Water Connection 
  Filtered Water highly recommended 
D =  Drain Connection