Specifications

Maintenance
35
Component Resistance Readings
Part Name Ohms
24VDC Power Supply, Across +V
& -V (Unwired DC Voltage)
326
24VDC Power Supply, Across L &
N (Unwired Line Voltage)
0.6
Control Transformer
(Primary)
25
Control Transformer
(Secondary)
0.6
Element, (Single element) 24
Element, (At contactor) 32.5
Heating Contactor Coil 6
Water Solenoid Valve 178
Cooling Fan 3.7
Part Name Ohms
Convection Motor Windings
Blue to Black
6.2
Connection Motor Windings
Brown to Black
6.2
Connection Motor Windings
Brown to Blue
6.2
Circuit Breaker Trip Coil 3.7
Vent Solenoid 30
Step Down Transformer
(Primary)
2
Step Down Transformer
(Secondary)
1
NOTE: Readings may vary some based on meter
capability and accuracy.