Specifications
Maintenance
29
Second Level Programming
NOTE: The oven must be in the ON position in orĆ
der to run the 2nd level programming
Press Maint Key Scroll with or keys to "Factory Program"
Press Ok Enter Code "3228"
Press Ok Scroll to "Appliance Type"
Press Ok Use or to set to "Electric"
Press Ok Scroll to "Boiler Enable"
Press Ok Use or to set to "No"
Press Ok Scroll to "Quench Enable"
Press Ok Use or to set to "No"
Press Ok Scroll to "Exit"
Press Ok Scroll to "Service"
Press Ok Enter Service Code "7378"
Press Ok Scroll to "Diagnostic Output"
Press Ok
Press and hold each button
below to test the function listed
on the right:
(Component Tested)
See "Trouble Shooting Test Points" for output testing if necessary
Temp Heat On (Fan High Fwd, Hot Air, Hot Air Enable, Hot Air Contactor)
Combi Fan Speed Gentle Forward (20 Hz)
Fan Fan Speed Low Forward (30 Hz)
Prog Fan Speed High Forward (40 Hz)
1 Fan Speed Turbo Forward (50 Hz)
4 Fan Speed High Reverse (Ć40 Hz)
7 Light
Light Spritzer
Esc Cooling Fan
2 Vent
5 Hot Air
8 Hot Air Enable
0 Quench
Time Cook Done