User guide

2
Installation
Description and Specications
ELECTRICAL RATINGS- CTB-G, CTBR-G, CTB-GFB & CTBR-GFB
HZ
VOLTAGE
KW
PHASE
MAX LOAD (AMPS) ELECTRICAL CONNECTION
AWG*
L1 L2 L2 N
CTB-G or CTBR-G
60
208
16.8 1 75 0 75 2
16.8 3 43 43 43 6
240
16.8 1 65 0 65 3
16.8 3 38 38 38 6
CTB-GFB or CTBR-GFB
60
208
17.6 1 85 0 85 1
17.6 3 49 49 49 4
240
17.6 1 73 0 73 2
17.6 3 42 42 42 6
* Electric connection wiring is sized for 60ºC copper wire at 125% of rated input.
NOTE: Double units can have phase loads partially equalized by matching lines during hook-up. Otherwise, CTB-Double
or CTBR-Double load ratings are twice the above data.
The Blodgett Cooktop models offer versatility of convection and range top cooking within a small footprint.The Blodgett
Cooktop is offered in four different congurations:
CTB-GFB - CTB oven base with 18” griddle on the left and 2 french top burners on the right
CTBR-GFB - CTBR oven base with 18” griddle on the right and 2 french top burners on the left
CTB-G - CTB oven base with 30” wide griddle
CTBR-G - CTBR oven base with 30” wide griddle