Specifications

Installation
5
Owner’s Responsibilities
1. Oven(s) are uncrated, stacked (if applies) and
put in place.
NOTE: Please refer to Leg Attachment and
Stacking Addendum.
2. The owner/operator must have the following
plumbing and electrical requirements met and
installed.
NOTE: Refer to the Utility Connection infor-
mation provided.
WARNING!!
Improper installation, adjustment, alter-
ation service or maintenance can cause
property damage, injury or death. Read
the installation, operation and mainte-
nance instructions thoroughly before
installing or servicing this equipment.
PLUMBING
Water
Water Pressure (min/max) 40 PS I min / 50 PSI max
Cold Water Connection 3/4” Hose Fitting, 3/8” ID hose minimum
Water Regulator Setting 35 PSI static
Mimimum requirements TDS --- less than 100 parts per million
Total Hardness --- 80-120 parts per million
Chlorine ---less than 30 parts per million
pH Factor --- 7.0-8.0
Drainage Atmospheric Vented Drain
Drain Connection 2” Copper
Avg Water Drain Temp. Approximately 122_F/50_C
ELECTRICAL
COS-6 COS-101 COS-101S
Electrical 9.4 kw 18.5 kw 18.5 kw
Amp/line (max) Amp/line (max) Amp/line (max)
Volt
3
Phase
1
Phase
Volt
3
Phase
1
Phase
Volt
3
Phase
1
Phase
208 26 45 208 52 89 208 52 89
240 23 40 240 45 77 240 45 77
480 23 N/A 480 23 N/A
Blower Motor .33 HP / .4 kW .5 HP / .5 kW .5 HP / .5 kW