Specifications
Maintenance
35
Deliming
NOTE: The following procedures apply to models
BC14E and BC14G only.
DELIMING WITHOUT OPTIONAL ELECTRIC
DELIMING PUMP
NOTE: The Delime lamp must be flashing to start
this process.
1. Be sure the delime solution reservoir is filled
with nonĆdiluted deliming agent such as
Lime Away" by EcoĆLabs or Lime Out", by
US Chemical.
2. Remove the cap from the appliance. Attach
the pump hose end to the deliming port. See
Figure 20.
3. Pump in the deliming agent into the appliance
by pulling up fully then pushing down on the
pump handle. Each up then down action
equals (1) One pump. Use the following table.
Model Ounces (pump)
BC14E 16 ounces (1 pump)
BC14G 16 ounces (1 pump)
4. Be sure the door is open.
5. Turn the oven into Cool Down mode. Press
and release the On Demand Steam button.
The Delime lamp will flash faster, acknowledgĆ
ing the action.
6. Turn the oven to the OFF mode.
The remainder of the procedure is automatic. The
Delime lamp will stay illuminated while the process
is active. When the process is completed, the DeĆ
lime lamp will turn off indicating the appliance can
now be used normally.
See View A
View A
See
View A
Deliming
Pump
Hose
Deliming
Port
Deliming
Reservoir
Figure 20