Specifications

Installation
21
Final Check Lists
OVEN OPERATIONAL TESTS
NOTE: Checks to be made by customer or authoĆ
rized service agent.
Cool Down Mode
j Check that the fan runs with the door open.
Steam Mode
Turn on STEAM mode and set thermostat to
steam. Verify the following:
j Heat demand lamp is on.
j Heat demand lamp shuts off at approximately
212_F (100_C).
j Check timer operation in all three positions
a.) Set timer to OFF" position, buzzer should
sound.
b.) Set timer in position other than OFF" or
STAY ON", timer should count down.
c.) Set timer in STAY ON" position, oven
should operate continuously without timer.
j Run light (power light) turns on.
j Unit produces steam, window fogs, door seal
does not leak.
Combi Mode
Turn to COMBI mode, set thermostat to 350_F
(177_C) and verify:
j Heat demand lamp is on.
j Oven is heating.
j Heat demand lamp shuts off at 350_F (177_C)
and oven maintains 350_F (177_C).
j Fan shuts off with door open.
Hot Air Mode
Turn to HOT AIR mode and set thermostat to
400_F (204_C) and verify:
j Heat demand lamp is on.
j Oven is heating.
j Heat demand lamp shuts off at 400_F (204_C)
and oven maintains 400_F (204_C).
j Fan shuts off with door open.
Steam On Demand Mode
Turn the oven to Hot Air mode. Set Steam On DeĆ
mand for 1 minute. Press the Steam On Demand
button and verify:
j Steam demand lamp is on.
j Steam demand lamp shuts off after approxiĆ
mately 1 minute.