Specifications

Installation
14
Plumbing Connections
WATER CONNECTION
NOTE: Hot water maximizes steam production but
is not required. Cold water may be supplied
to both inlets if hot water is not available.
Connect the appliance to quality water via a presĆ
sure hose with 3/4" (19mm) couplings. See
Figure 7 for connections. A shut off valve is to be
provided adjacent to the oven.
WARNING!!
Operating the appliance without the water
regulator installed will invalidate your warĆ
ranty.
BC14E
Cold
Water
BC14G
Cold Water
Water Connections
Rear of Appliance
B14G
Filtered
Connection
Unfiltered
Connection
Cold Water
Figure 7
This product must be installed by a licensed
Plumber or Gas Fitter when installed within the
Commonwealth of Massachusetts.
DRAIN CONNECTION
The steam vent assemblies are constructed of 2"
DWV copper piping reduced to 1Ć1/2 DWV pipe.
The steam vent should be run to an open floor
drain avoiding flexible hose that could sag and alĆ
low trapped water to accumulate. The customer
must supply the piping from the oven to the drain.
Connect drip pan drain to main drain using the 12"
flexible hose with hose clamps provided.
Use the drain vent assembly and a 2" (50.8mm)
pipe for drain connection.
Customer supplied
2" (50.8mm) drain
waste vent piping
Coupling
Figure 8
Specific water/drain connection for City of Los
Angeles
1. Each drain line from the appliance shall be
routed without dips or sags to terminate above
the flood level rim of an approved indirect waste
receptor.
2. The appliance shall be installed in accordance
with the manufacturer's printed instructions
and the LAPC and LAMC, 1999 editions.
3. A backflow protection device may be required
by local codes. If so, install on the potable water
system directly ahead of the appliance. The
backflow protection device shall be any of the
following: an approved pressure type vacuum
breaker installed at least 12" above the highest
point of use, a double check valve backflow preĆ
venter or a reduced pressure principal backflow
preventer.