Repair manual
INSTALLATION
9 --- 2
RATINGS -- ELECTRIC APPLIANCES -- BC14E/AA and BC14EDS/AA
Voltage Hz Phase
Max Load (amps)
Motor
L1 L2 L3
208 60 1 89 89 --- 1/2HP 208-240VAC , 50/60 Hz
208 60 3 52 52 52 1/2HP 208-240VAC, 50/60 Hz
240 60 1 82 82 --- 1/2HP 208-240VAC , 50/60 Hz
240 60 3 47 47 47 1/2HP 208-240VAC, 50/60 Hz
480 60 3 23 23 23 1/2HP 208-240VAC, 50/60 Hz
380/220 50 3 25 25 25 1/2HP 208-240VAC, 50/60 Hz
415/240 50 3 27 27 27 1/2HP 208-240VAC, 50/60 Hz
400/230 50 3 26 26 26 1/2HP 208-240VAC, 50/60 Hz
TABLE 4
OVEN LOCATION AND LEVELING
OVEN LOCATION
The well planned and proper placement of your
oven will result in long term operator convenience
and satisfactory performance.
Certain minimum clearances must be maintained
between the oven and any combustible or non -
combustible construction. See the table below.
In addition, the following clearances are recom-
mended for servicing.
D
Oven body sides --- 12” (30cm)
D
Oven body back --- 12” (30cm)
Left Side Heat Shield
Heat sources should not be near the air vents lo-
cated on the left hand side of the gas appliance.
Consult the factory for optional protective side heat
shield.
BC14E P/N R9527
Oven
M
d
l
MINIMUM REQUIRED
CLEARANCES
Model
Right Side Left Side Back
BC14E 1”
(25.4mm)
4”
(101.6mm)
6”
(152.4mm)
OVEN LEVELING
This oven should be set up in place.
With any stand or oven, be certain that the surface
is level, even and solid. A sloped or uneven base
may cause the appliance t o function improperly.
Minor unevenness can be corrected by adjusting
the metal leg feet. The maximum adjustment of the
leg feet is 1-3/8” (35mm).
Maximum
Adju stment
1-3/8” (35mm)
Leg
F oot
FIGURE 1