Repair manual

BC14E
8 --- 3
BC14E SAFETY LIMITS FL OW CHART
Mode Switch
23
24
Hot air
Combi
Cool
Steam
Down
P13
P
P
N
N
G
L1
L2
Door
Switch
S2
24
25
26
Fan speed
SW
R5
4
2
Buzzer
T1
3
9
21
4
10
22
S
Hot air
Combi
team
Mode Switch
Combi
5
6
11 12
7
8
17
18
19
20
Steam
6
7
tm1
4
5
6
T I M E R --- S 5
A
B
C
I
1shot
D
E
Motor
G
H
Open at 176_F(80_C)
Close at 149_F(65_C)
F3
662_F (350_C)
H4
Power on
03
5.6K
--- 7
A
Noise Filter
F
G
Speed Control
Delime
S15
FIGURE 1