Repair manual
BC14G
1 --- 1
INSTALLATION SPECIFICATIONS/INFORMATION
Before starting to troubleshoot an oven, verify the
oven has been installed correctly. The installation of
the electric and gas co nnectio ns must be performed
by a qualified installer only. The installation must con-
form to all loc al and national install ati o n standards. A
hood sy stem is requi red with the BC14G.
MAXIMUM SHELF LOADING
BC14G 100 lbs (45.5 Kg)
TABLE 1
PLUMBING SPECIFICATIONS -- BC14G/AA
Water
Water Pressure 30 PSI (207 kPa) minimum
50 PSI (345 kPa) maximum
Water Connection 3/4” Hose Hot a nd Cold Water
Water Regulator Setting Preset to 20 PSI (138 kPa)
Drainage Atmospheric Vented Drain
Drain Connection 2.00” (50.8mm) Copper
Avg Water Drain Temp. Approximately 160 _F(71_C)
TABLE 2
PLUMBING SPECIFICATIONS -- B C14GDS/AA
Water
Water Pressure 30 PSI (207 k Pa) minimum
50 PSI (345 kPa) maximum
Water Connection 3/4” Hose Cold Water
Water Regulator Setting Preset to 20 PSI (138 kPa)
Drainage Atmospheric Vented Drain
Drain Connection 2.00” (50.8mm) Copper
Avg Water Drain Temp. Approximately 160 _F(71_C)
NOTE: For steam requirements see page 1 ---5 STEAM CONNECTION for the BC14GDS.