Repair manual

TROUBLESHOOTING
3 --- 1 2
BC14G TIMER SETTINGS
Remove dial section
TOP VIEW
SIDE
VIEW
SIDE
VIEW
Inside if dial section
meter
A
B
C
D
Dial
L
R
A) Top view of Timer.
NOTE: The L & R there are two timer adjustments per timer.
B) Side view of timer.
C) Side view with dial section removed. Carefully remove dial section with a pair of pliers.
D) Inside of the dial section there are two terminals. Use your meter on the ohms setting.
Turn the dial until to the desired ohms value. Reattach the dial section and test unit.
1
23
4
1
23
4
FIGURE 10
T2 Steam duty cycle In combi mode.
L) is 375K OHMS Steam ON 45 seconds.
R) is 666K OHMS Steam OFF 80 seconds.
T3 One shot steam
NOTE: Set by timer on front panel.
T4 Flush timer
L) Is 150K OHMS Flush ON 90 seconds.
T5 Hot air duty cycle. In steam mode .
L) is 375K OHMS Hot air ON 45 seconds
R) is 500K OHMS Hot air OFF 60 seconds