Repair manual
BC14G AND BC14E
2 --- 3
DELIMING
WARNING!!
Deliming solutions are hazardous and
can cause burns to the skin and eyes.
Wear protective clothing and eyewear
when decalcifying your appliance.
Deli ming of the steam generator is the single most im-
portant preventative maintenance task. Lime will build
up inside the steam generator, reducing efficiency and
causing damage to the level control system.
WARNING!!
Problems caused by insufficient monthly
deliming are not covered by the warranty.
WARNING!!
DO NOT actuate the deliming switch un-
lesstheovenisintheOFFmode.
To decalcify your appliance:
1. Turn appliance t o the STEAM mode until steam
is produced.
2. TurntheapplianceOFF.
3. Move the deli ming switch to the DELIME posi tion.
4. The deliming chemical has a chart on the con-
tainer for the chemical to total water volume ra-
tio. The total water volume for your unit is mea-
sured in quarts and is listed next to your unit
identification on the deliming pump.
Oven
Model
To ta l Wa t er
Volume
Water and
Deliming Solution
BC14E 23 qrts 8qrts
BC14G 13 qrt s 4qrts
5. Pour the proper amount of deliming chemical
into the deliming pump reservoir.
6. Now add the proper amount of water into the
deliming pump.
7. Attach the hose from the deliming pump to the
deliming port.
8. Slowly pump the deliming solution and water
mixture into the appliance.
9. Disconnect the pump hose from the appliance.
10. Wait 1/2 to 1 hour.
11. Move the deliming switch to the RUN position.
The appliance will automatically flush the
steam generator for 90 seconds.
12. After the unit flushes for 90 seconds, clean the
deliming pump and deliming port. Fill the de -
liming reservoir to the SYSTEM FLUSH level
with tap water.
13. Attach the deliming hose to the deliming port.
Slowly pump in the tap water to flush the delim-
ing connector and pump a ssembly.
14. Disconnect the deliming pump assembly from
the unit.
15. Press and hold the Drain/Flush switch in the
Flush position for 30 seconds.
See View A
View A
See
View A
Deliming
Pump
Hose
Deliming
Port
Deliming
Solution
Reservoir
Deliming
Switch
Push Tab
to release
FIGURE 3