Repair manual
INTRODUCTION
1-2
ELECTRICAL SPECIFICATIONS
Wiring diagrams are located in the blower comĆ
partment area.
Ovens are supplied for operation in several voltage
choices, single or three phase grounded circuits.
The electric motor, indicator lights and related
switches are interconnected through the one powĆ
er source supplied to the oven.
1. The supply conduit enters through the rear of
the oven and electrical block secured to the
perforated panel at the back of the control
compartment.
THE BLODGETT OVEN COMPANY CANNOT ASĆ
SUME RESPONSIBILITY FOR LOSS OR DAMAGE
SUFFERED AS A RESULT OF IMPROPER INSTALĆ
LATION.
Amperes
Electrical
Connection
KW/Section Volts Phase
L1 L2 L3 N
C
onnection
AWG*
60 HZ UNITS
5.6 208 1 27 - 27 - 8
5.6 208 3 24 12 15 - 10
5.6 220Ć240 1 24 -24- 8
5.6 220Ć240 3 21 11 14 - 10
8.0 208 1 35 -35- 6
8.0 208 3 22 20 21 - 10
8.0 220Ć240 1 32 -32- 6
8.0 220Ć240 3 20 18 19 - 10
50 HZ UNITS
5.6 208 1 27 - 27 -
5.6 220-240 1 24 --24
8 220-240 1 35 --35
5.6 220/380 3 10 882
8 220/380 3 14 12 12 2
Size per
lld
5.6 240/415 3 10 773
local codes
8 240/415 3 13 11 11 2
5.6 230/400 3 9 881
8 230/400 3 13 11 11 2
NOTE: *Electric connection wiring is sized for 90_C copper wire at 125% of rated input.
NOTE: Double units can have phase loads partially equalized by matching lines during hookĆup. OtherĆ
wise, CTBĆDouble or CTBRĆDouble load ratings are twice the above data.