Specifications

3
Installation
ELECTRICAL RATINGS - GAS OVENS
BCX-14G/AA, BX-14G/AA AND CNVX-14G/AA
TYPE OF GAS GAS INPUT VOLTAGE PHASE AMPS MOTOR
BCX-14G/AA
Natural Steam - 50,000 BTU/Hr
Hot Air - 65,000 BTU/Hr
Total - 115,000 BTU/Hr
115
208-240
1
1
12
6
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
Propane Steam - 48,000 BTU/Hr
Hot Air - 65,000 BTU/Hr
Total - 113,000 BTU/Hr
115
208-240
1
1
12
6
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
BX-14G/AA and CNVX-14G/AA
Natural Hot Air - 65,000 BTU/Hr 115
208-240
1
1
12
6
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
Propane Hot Air - 65,000 BTU/Hr 115
208-240
1
1
12
6
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
3/4” NPT connector for all U.S. and Canadian installations
RATINGS - ELECTRIC APPLIANCES
BCX-14E/AA, BX-14E/AA AND CNVX-14E/AA
VOLTAGE
HZ
KW
PHASE
MAX LOAD (AMPS
MOTOR
L1 L2 L2
208 60 19 3 53 53 50 3/4 HP 208-240VAC, 50/60 Hz
240 60 19 3 46 46 43 3/4 HP 208-240VAC, 50/60 Hz
480 60 19 3 23 23 21 3/4 HP 208-240VAC, 50/60 Hz
Owners Responsibilities