Specifications

2
Installation
PLUMBING SPECIFICATIONS
BCX-14G/AA, BCX-14E/AA
BX-14G/AA, and BX-14E/AA
CNVX-14G/AA
CNVX-14E/AA
WATER
Water pressure 40 PSI minimum
50 PSI maximum
Water connection 3/4” garden hose - Hot and Cold water 3/4” garden hose for spray hose - Cold
water only
Water pressure regulator setting Preset to 30 PSI (207 kPa)
Minimum requirements TDS: 40-125 ppm
Hardness: 35-100 ppm
Chlorides: <25 ppm
Silica: <13 ppm
Chlorine: <0.2 ppm
Chloramine: <0.2 ppm
pH: 7.0-8.5
DRAINAGE
Drain type Atmospheric Vented Drain
Drain connection 2.00” (50.8mm) Copper
Maximum water drain temperature 140ºF (60ºC)
Owners Responsibilities
INSTALLATION RESPONSIBILITIES PRIOR TO SERVICE STARTUP INSPECTION
You are entitled to a free start-up inspection service by
our factory ASAP. Before a factory representative arrives
to perform a startup procedure, the owner must already
have satised the following requirements.
1. Oven(s) are uncrated, stacked (if applies) and put in
place.
NOTE: Please refer to Leg Attachment and Stacking.
Maximum shelf loading - 60 lbs (27.3 Kg)