Specifications

10
Installation
Plumbing Connections
WATER CONNECTION
NOTE: Hot water maximizes steam production but is not
required. Cold water may be supplied to both
inlets if hot water is not available.
Connect the appliance to quality water via a pressure
hose with 3/4” GHT (19mm) couplings. See below for
connections. A shut off valve is to be provided adjacent
to the oven.
WARNING!!
Operating the appliance without the water reg-
ulator installed will invalidate your warranty.
This product must be installed by a licensed Plumber or
Gas Fitter when installed within the Commonwealth of
Massachusetts.
DRAIN CONNECTION
The drain should be run to an open oor drain avoiding
exible hose that could sag and allow trapped water to
accumulate. The customer must supply the piping from
the oven to the drain.
Specic water/drain connection for City of Los Ange-
les
1. Each drain line from the appliance shall be routed
without dips or sags to terminate above the ood level
rim of an approved indirect waste receptor.
2. The appliance shall be installed in accordance with
the manufacturer’s printed instructions and the LAPC
and LAMC, 1999 editions.
3. A backow protection device may be required by lo-
cal codes. If so, install on the potable water system
directly ahead of the appliance. The backow protec-
tion device shall be any of the following: an approved
pressure type vacuum breaker installed at least 12”
above the highest point of use, a double check valve
backow preventer or a reduced pressure principal
backow preventer.
Figure 8
BCX-14G and BX-14G
CNVX-14G
BCX-14E and BX-14E
CNVX-14E
Gas connection
Electrical connection
Filtered/boiler
connection
Unltered/condensate
and spray hose
connection