Programming instructions
CONVECTION OVEN CONTROLS
1-46
Programming the setback mode
The setback mode operates as a power saving feaĆ
ture. After a period of nonĆuse (the setback time) the
oven temperature automatically decreases to the
setback temperature. The oven will maintain this
temperature until a product key is pressed.
1. The top display reads SEtb. The bottom display
gives the setback mode. To change the setback
press the TOGGLE/CLEAR KEY (10). The botĆ
tom display toggles between YES and no. Press
the SCAN KEY (14).
If no is chosen:
A.) The controller advances to programming the
temperature mode.
If yes is chosen:
A.) The bottom display gives the current setĆ
back time. Press the TOGGLE/CLEAR KEY
(10). Use the product keys to the enter the
desired setback time. Press the SCAN KEY
(14) to enter the new setback time.
NOTE: The minimum setback time is 20:00. The
maximum setback time is 59:59.
B.) The bottom display gives the current setĆ
back temperature. Press the TOGGLE/
CLEAR KEY (10). Use the product keys to
the enter a setback temperature from
140_F-300_F. Press the SCAN KEY (14) to
enter the new setback and continue with
programming the temperature mode.
Programming the temperature mode (_F or _C)
1. The top display reads dEg. The bottom display
gives the units. To change the units press the
TOGGLE/CLEAR KEY (10). The bottom display
toggles between F and C.
2. Press the SCAN KEY (14) to enter the new temĆ
perature units and continue programming the
oven size.
Programming the oven size
1. The top display reads APPL. The bottom display
reads either FULL or HALF. Press the TOGGLE/
CLEAR KEY (10) until the bottom display reads
HALF for the CTBRĆAP.
2. Press the SCAN KEY (14) to enter the oven size
and continue with exiting the programming
mode.
Exiting the programming mode
1. The top display reads SYS. Press the PROG KEY
(9). The control returns to the operating standby
mode.
Parameter Default
Hold mode NO
Setback NO
Temperature Units _F
Appliance Size HALF
TABLE 3
PROGRAMMING THE OFFSET
Entering the offset programming mode
1. Press the PROG KEY (9). The top display reads
CodE.
2. Use the product keys to enter the offset programĆ
ming access code: 4 5 2 3. Press the ENTER KEY
(13). The top display reads oFF. The bottom disĆ
play reads SEt.
Programming the temperature offset
1. Press the SCAN KEY (14). The top display reads
oFST. The bottom display reads either xxF or
-xxF.
2. Press the TOGGLE/CLEAR KEY (10) to toggle
between positive and negative. Use the product
keys to the enter the desired temperature offset.
3. Press the SCAN KEY (14) to enter the new temĆ
perature offset.
Exiting the offset programming mode
1. Press the PROG KEY (9). The control returns to
the operating standby mode.