Programming instructions
CONVECTION OVEN CONTROLS
1-44
Programming the Timing Mode:
NOTE: It may be necessary to press the ENTER KEY
(13) until the top display reads tC-1.
There are 3 options for timing mode: Straight, Flex
and Sensitivity.
1. The top display reads tC-1. The bottom display
gives the current timing mode. Press the
TOGGLE/CLEAR KEY (10) to toggle between St,
FL and SEns.
2. Press the ENTER KEY (13) to save the new timĆ
ing mode for stage 1. The top display reads
tC-2.
NOTE: Repeat Steps 1-2 to program the timing
mode for additional stages.
3. When the timing mode for the final stage has
been entered press the SCAN KEY (14).
If no sensitivity cycles are selected the control
advances to PreAlarms.
If sensitivity is used, the control returns to the first
stage programmed with sensitivity. Follow Step
4 to program the sensitivity level.
4. The top display reads SE-1. Use the product
keys to enter the desired sensitivity from 0-9.
Press the SCAN KEY (14). The control advances
to the next stage programmed for sensitivity.
NOTE: Repeat Step 4 to program sensitivity levĆ
els for all applicable stages. When the fiĆ
nal sensitivity level has been entered the
control advances to PreAlarms.
Programming the PreAlarms:
A PreAlarm is an alarm that sounds during the cook
cycle. PreAlarms can be used to alert the operator
that the product needs to be turned or stirred, etc. Up
to three PreAlarms can be programmed for each
product.
1. The top display reads A1__. (The __ indicate the
product key) The bottom display gives the alarm
time. Use the product keys to enter the desired
time for the first alarm. Press the ENTER KEY (13)
to enter the PreAlarm time.
NOTE: PreAlarm times are measured from the
end of the total cook time. For example
if the total cook time is 30:00 and a PreAĆ
larm of 5:00 is entered, the alarm will
sound 25 minutes into the cook cycle. If
a PreAlarm of 0:00 is entered, no addiĆ
tional PreAlarms may be programmed
for the selected product key.
2. Press the SCAN KEY (14).
3. The top display reads AUTO. The bottom display
reads either YES or no. Press the TOGGLE/
CLEAR KEY (10) to toggle between YES and no.
Press the SCAN KEY (14) to enter the PreAlarm
type.
NOTE: An auto PreAlarm sounds for approxiĆ
mately 5 seconds, then shuts off autoĆ
matically. For manual PreAlarms the opĆ
erator must press the product key to
silence the alarm.
4. The top display reads A2__. Repeat steps 1-3
for the second and third PreAlarm. When all
PreAlarms have been entered the control adĆ
vances to programming the head count.