Programming instructions
CONVECTION OVEN CONTROLS
1-8
1. The top display reads CYC1. The bottom display
gives the current fan cycle. Press the TOGGLE/
CLEAR KEY (11). The bottom display toggles beĆ
tween PULS, HEAt and FULL.
2. If heat or full are selected press the SCAN KEY
(15) to save the new fan cycle and advance to
timing mode.
If pulse is selected press the SCAN KEY (15) and
continue with Steps 3-4 to program the pulse
cycle.
3. The top display reads on-1. The bottom display
gives the current pulse on time. Use the product
keys to enter the desired pulse on time from 10
to 60 seconds. Press the SCAN KEY (15).
4. The top display reads of-1. The bottom display
gives the current pulse off time. Use the product
keys to enter the desired pulse off time from 10
to 60 seconds. Press the SCAN KEY (15) to adĆ
vance the programming mode to shelf mode.
Programming the Shelf ID:
The Shelf ID option can be turned on or off for specific
product keys.
NOTE: Shelf ID is not allowed with multiple stage
recipes.
1. The top display reads SHLF. The bottom display
reads the current shelf ID mode. Press the
TOGGLE/CLEAR KEY (11) to toggle between
yes and no. Press the SCAN KEY (15) to advance
the programming mode to timing.
Programming the Timing Mode:
There are 3 options for timing mode: Straight, Flex
and Sensitivity.
1. The top display reads tC-1. The bottom display
gives the current timing mode. Press the
TOGGLE/CLEAR KEY (11) to toggle between St,
FL and SEns.
NOTE: Sensitivity adjusts the cook time to comĆ
pensate for any difference between the
setpoint and actual temperature. The
lower the sensitivity value the shorter the
time adjustment. Sensitivity values are
set in the manager level programming.
If Shelf ID is activated, all three timing modes are
available. If Shelf ID is not activated, only straight
or flex timing modes are available.
2. Press the SCAN KEY (15) to advance the proĆ
gramming mode to hold mode.
Programming Hold Mode:
The hold mode can be toggled on or off for specific
product keys.
1. The top display reads HOLD. The bottom display
reads the current hold mode. Press TOGGLE/
CLEAR KEY (11) to toggle between on and off.
Press the SCAN KEY (15).
2. If the hold mode is activated, the bottom display
give the current hold time. Press the TOGGLE/
CLEAR KEY (11). Use the product keys to enter
the new hold time. Press the SCAN KEY (15).
3. The bottom display gives the current hold temĆ
perature. Press the TOGGLE/CLEAR KEY (11).
Use the product keys to enter the new hold temĆ
perature from 140Ć210_F (60Ć99_C). Press the
SCAN KEY (15).
4. The top display reads HFAN (hold fan speed).
The bottom display gives the current hold fan
speed setting. Press the TOGGLE/CLEAR KEY
(11) to toggle between high and low. Press the
SCAN KEY (15) to exit the hold mode programĆ
ming.
Check all Settings (SEE Mode):
The SEE mode allows the operator to scroll through
and view settings of a particular product key.
1. Press the PROG KEY (10). The top display reads
Code.
2. Use the product keys to enter the SEE access
code: 2 4 4 4. Press the ENTER KEY (14). The top
display reads SEE.
3. Press the product key you wish to view. Press the
ENTER KEY (14).
4. The control will automatically scroll through the
programmable features showing the proĆ
grammed values for each.
Exiting the programming mode:
1. The top display reads Prod. Press the PROG KEY
(10). The control returns to operating mode.