User manual

Page 7
The Puck CSI Xtreme User Manual Rev. A Copyright (c) 2013 Blizzard Lighting, LLC
3. SETUP
Fuse Replacement
Withaatheadscrewdriver,wedgethe
fuse holder out of its housing. Remove the
damaged fuse from its holder and replace
with exact same type fuse. Insert the fuse
holder back in its place and reconnect
power.
Connecting A Bunch of Puck CSI™ Xtreme Flat LED PAR Cans
You will need a serial data link to run light shows using a DMX-512
controllerortorunshowsontwoormorexturessettosyncinmas-
ter/slaveoperatingmode.Thecombinednumberofchannelsrequired
byallthexturesonaserialdatalinkdeterminesthenumberofx-
tures the data link can support.
Fixtures on a serial data link must be daisy chained in one single line.
Also,connectingmorethan32xturesononeserialdatalinkwithout
the use of a DMX optically-isolated splitter may result in deterioration
of the digital DMX signal.
The maximum recommended cable-run distance is 500 meters (1640
ft).Themaximumrecommendednumberofxturesonaserialdata
linkis32xtures.
Data/DMX Cabling
Tolinkxturestogetheryou’llneeddatacables.Youshouldusedata-
gradecablesthatcancarryahighqualitysignalandarelessproneto
electromagnetic interference.
Forinstance,Belden©9841meetsthespecicationsforEIARS-485
applications. Standard microphone cables will “probably” be OK, but
note that they cannot transmit DMX data as reliably over long distanc-
es. In any event, the cable should have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor & shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms