User's Manual

Page 9
MAX L™ User Manual - Rev. A © 2020 Blizzard Lighting, LLC
Fixture Linking (M/S Mode)
1. Connect the male connector side of the DMX cable to the output female
connector of the rst xture.
2. Connect the end of the cable coming from
the rst xture which will have a female
connector to the input connector of the next
xture consisting of a male connector. Then,
proceed to connect from the output as stated
above to the input of the following xture
and so on.
A quick note: Often, the setup for Master-Slave and
Standalone operation requires that the rst xture in the
chain be initialized for this purpose via either settings in the
control panel or DIP-switches. Secondarily, the xtures that
follow may also require a slave setting.
Check the “Operating Adjustments” section in this manual for complete
instructions for this type of setup and conguration.
DMX OUTDMX IN
First
Fixture
in Chain
Next
Fixture
in Chain
DMX OUTDMX IN
Mounting & Rigging
This xture may be mounted in any SAFE position provided there is enough
room for ventilation. The fan or vent pathway must never be obstructed.
IMPORTANT: Regardless of the rigging option you choose for your xtures,
always be sure to secure your xture with a safety cable.
Mount the xture using a suitable "C" or "O" type clamp. The clamps should be
rated to hold at least 10x the xture’s weight to ensure structural stability. Do
not mount to surfaces of unknown strength, and ensure properly rated rigging
is used when mounting xtures overhead.
Overhead mounting requires extensive experience, which includes calculating
working load limits, knowledge of the installation material being used, and
periodic safety inspections. If you lack these qualications, do not attempt the
installation yourself. Improper installation can result in bodily injury.
Bracket
Clamp
Safety Loop