User's Manual
Page 7
MAX L™ User Manual - Rev. A      © 2020 Blizzard Lighting, LLC
Fuse Replacement
With a at head screwdriver, wedge the fuse 
holder out of its housing. Remove the damaged 
fuse from its holder and replace with exact same 
type fuse.
Connecting A Bunch of MAX L's
You will need a serial data link to run light shows 
using a DMX-512 controller or to run shows on 
two or more xtures set to sync in master/slave operating mode. The combined 
number of channels required by all the xtures on a serial data link determines 
the number of xtures the data link can support.
Fixtures on a serial data link must be daisy chained in one single line. Also, 
connecting more than 32 xtures on one serial data link without the use of a 
DMX optically-isolated splitter may result in deterioration of the digital DMX 
signal. The maximum recommended cable-run distance is 500 meters (1640 
ft). The maximum recommended number of xtures on a serial data link is 32 
xtures.
Data/DMX Cabling
To link xtures together you’ll need data cables. You should use data-grade 
cables that can carry a high quality signal and are less prone to electromagnetic 
interference.
For instance, Belden© 9841 meets the specications for EIA RS-485 
applications. Standard microphone cables will “probably” be OK, but note that 
they cannot transmit DMX data as reliably over long distances. In any event, 
the cable should have the following characteristics:
  2-conductor twisted pair plus a shield
  Maximum capacitance between conductors – 30 pF/ft.
  Maximum capacitance between conductor & shield – 55 pF/ft.
  Maximum resistance of 20 ohms / 1000 ft.
  Nominal impedance 100 – 140 ohms
Before replacing a fuse, disconnect the power cord. 
ALWAYS replace with the same type and rating of fuse.
3. SETUP